2004•PubMedRequires access

[Study on the response of specific antibodies against SARS-CoV in patients infected with SARS].

Panyong Mao, Lei Zhu, Youchun Wang, Jun Hou, Yan Hu, Honghui Shen, Shaojie Xin, Baosen Li, Yuanli Mao, Hui Sheng Zhuang

Open publisher page 1 citations

Abstract

OBJECTIVE: To study the response of specific antibodies against severe acute respiratory syndrome (SARS)-CoV in patients infected with SARS. METHODS: IgM-capture, indirect and antigen-sandwiched enzyme linked immunosorbent assay (ELISA) were used to detect the SARS-CoV specific IgM, IgG and total antibodies in sera of clinical SARS patients or non-SARS individuals. RESULTS: The positive rates of IgM, IgG and total antibodies to SARS-CoV in 146 sera of SARS patients collected in different phases of the disease were 61.64%, 53.43% and 69.86%, respectively. The earliest detectable days after onset of the disease for IgM and IgG to SRAS-CoV were 7 and 12 days, respectively. The specific IgM disappeared as early as 42 days after the onset of SARS. Of 70 sera from hepatitis A patients, 2 showed false positive results, while 127 sera from other patients were all negative, detected by the 3 methods. Serum from one medical worker who had been close contact to SARS patients was positive for anti-SARS-CoV IgG and total antibodies. These 3 methods used for detection were all not influenced by rheumatoid factor (RF). CONCLUSION: All of the three methods were specific and sensitive for the detection of specific antibodies to SARS-CoV, and useful for epidemiological research and clinical diagnosis, but not for early diagnosis of SARS.

About this research paper

What this paper is about

OBJECTIVE: To study the response of specific antibodies against severe acute respiratory syndrome (SARS)-CoV in patients infected with SARS. METHODS: IgM-capture, indirect and antigen-sandwiched enzyme linked immunosorbent assay (ELISA) were used to detect the SARS-CoV specific IgM, IgG and total antibodies in sera of clinical SARS patients or non-SARS individuals. RESULTS: The positive rates of IgM, IgG and total antibodies to SARS-CoV in 146 sera of SARS patients collected in different phases of the disease were 61.64%, 53.43% and 69.86%, respectively. The earliest detectable days after onset of the disease for IgM and IgG to SRAS-CoV were 7 and 12 days, respectively. The specific IgM disappeared as early as 42 days after the onset of SARS. Of 70 sera from hepatitis A patients, 2 showed false positive results, while 127 sera from other patients were all negative, detected by the 3 methods. Serum from one medical worker who had been close contact to SARS patients was positive for anti-SARS-CoV IgG and total antibodies. These 3 methods used for detection were all not influenced by rheumatoid factor (RF). CONCLUSION: All of the three methods were specific and sensitive for the detection of specific antibodies to SARS-CoV, and useful for epidemiological research and clinical diagnosis, but not for early diagnosis of SARS.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To study the response of specific antibodies against severe acute respiratory syndrome (SARS)-CoV in patients infected with SARS. METHODS: IgM-capture, indirect and antigen-sandwiched enzyme linked immunosorbent assay (ELISA) were used to detect the SARS-CoV specific IgM, IgG and total antibodies in sera of clinical SARS patients or non-SARS individuals. RESULTS: The positive rates of IgM, IgG and total antibodies to SARS-CoV in 146 sera of SARS patients collected in different phases of the disease were 61.64%, 53.43% and 69.86%, respectively. The earliest detectable days after onset of the disease for IgM and IgG to SRAS-CoV were 7 and 12 days, respectively. The specific IgM disappeared as early as 42 days after the onset of SARS. Of 70 sera from hepatitis A patients, 2 showed false positive results, while 127 sera from other patients were all negative, detected by the 3 methods. Serum from one medical worker who had been close contact to SARS patients was positive for anti-SARS-CoV IgG and total antibodies. These 3 methods used for detection were all not influenced by rheumatoid factor (RF). CONCLUSION: All of the three methods were specific and sensitive for the detection of specific antibodies to SARS-CoV, and useful for epidemiological research and clinical diagnosis, but not for early diagnosis of SARS.

Key concepts: Medicine, Antibody, Immunology, Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), Specific antibody, Antigen, Respiratory system, Rheumatoid factor

Related papers

Back to paper searchBrowse research topicsOriginal source
[Study on the response of specific antibodies against SARS-CoV in patients infected with SARS]. — Research Paper | ScholarLens