2010•Journal of Shandong UniversityRequires access

A numerical model analysis and optimization of layout for a mechanical ventilating cooling tower

Wei Wang

Open publisher page 0 citations

Abstract

The spacing distance between two parallel mechanical ventilating cooling tower rows was designed too large according to the relevant Chinese Design Codes in the Indonesian 4×600MW Thermal Power Plant.A mathematical model experiment was made to analyze the influence of local practical environment factor and spacing distance of tower row on cooling effort,evaluate the environmental wind's influence on reflux and disturbance of exhaust wet air in different cooling tower row layouts,and optimize the cooling tower row layout.It was concluded that as its long axis parallels the dominate summer wind direction,the spacing distance has no influence on wet air reflux and spacing distance can be decreased from 51m to 21.6 m,and thereby the site area of the plant is reduced with guaranteed cooling effort.

About this research paper

What this paper is about

The spacing distance between two parallel mechanical ventilating cooling tower rows was designed too large according to the relevant Chinese Design Codes in the Indonesian 4×600MW Thermal Power Plant.A mathematical model experiment was made to analyze the influence of local practical environment factor and spacing distance of tower row on cooling effort,evaluate the environmental wind's influence on reflux and disturbance of exhaust wet air in different cooling tower row layouts,and optimize the cooling tower row layout.It was concluded that as its long axis parallels the dominate summer wind direction,the spacing distance has no influence on wet air reflux and spacing distance can be decreased from 51m to 21.6 m,and thereby the site area of the plant is reduced with guaranteed cooling effort.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The spacing distance between two parallel mechanical ventilating cooling tower rows was designed too large according to the relevant Chinese Design Codes in the Indonesian 4×600MW Thermal Power Plant.A mathematical model experiment was made to analyze the influence of local practical environment factor and spacing distance of tower row on cooling effort,evaluate the environmental wind's influence on reflux and disturbance of exhaust wet air in different cooling tower row layouts,and optimize the cooling tower row layout.It was concluded that as its long axis parallels the dominate summer wind direction,the spacing distance has no influence on wet air reflux and spacing distance can be decreased from 51m to 21.6 m,and thereby the site area of the plant is reduced with guaranteed cooling effort.

Key concepts: Cooling tower, Tower, Row, Airspeed, Wind speed, Marine engineering, Thermal, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
A numerical model analysis and optimization of layout for a mechanical ventilating cooling tower — Research Paper | ScholarLens