HPLC Method for Simultaneous Determination of Baicalin,Baicalein,Aloe Emodin and Emodin in Niuhuang Jiedu Tablets
Pan Li-l
Abstract
Pan Li-l
Abstract
Objective: To establish a method for the determination of multi- components( baicalin,baicalein,aloe emodin and emodin) in Niuhuang Jiedu tablets( NHJDT) and perfect the quality control standards. Methods: Using Agilent ZORBAX SB- C18( 4. 6 × 250 mm,5μm) as the separation column,the UV absorbance was monitored at 260 nm by injecting 10μL of the sample solution each time and the column temperature was maintained at 30℃. The flow rate was1. 0m L / min. Acetonitrile was as the mobile phase A; 0. 1% phosphoric acid was as mobile phase B for gradient elution.Results: The linear range in content determination of baicalin,baicalein,aloe emodin and emodin was followed by5. 06 ~ 202. 4μg / m L,1. 836 ~ 30. 6μg / m L,0. 196 ~ 7. 84μg / m L and 0. 992 ~ 19. 84μg / m L,the correlation coefficient R2 was in turn 0. 999 7,0. 999 1,0. 999 8 and 0. 999 8. The average recoveries were 99. 17%( RSD = 0. 72%),97. 46%( RSD = 0. 85%),97. 91%( RSD = 1. 97%),98. 23%( RSD = 0. 82%)( n = 6). Conclusion: The method is accurate and can be used to evaluate the quality of NHJDT.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: To establish a method for the determination of multi- components( baicalin,baicalein,aloe emodin and emodin) in Niuhuang Jiedu tablets( NHJDT) and perfect the quality control standards. Methods: Using Agilent ZORBAX SB- C18( 4. 6 × 250 mm,5μm) as the separation column,the UV absorbance was monitored at 260 nm by injecting 10μL of the sample solution each time and the column temperature was maintained at 30℃. The flow rate was1. 0m L / min. Acetonitrile was as the mobile phase A; 0. 1% phosphoric acid was as mobile phase B for gradient elution.Results: The linear range in content determination of baicalin,baicalein,aloe emodin and emodin was followed by5. 06 ~ 202. 4μg / m L,1. 836 ~ 30. 6μg / m L,0. 196 ~ 7. 84μg / m L and 0. 992 ~ 19. 84μg / m L,the correlation coefficient R2 was in turn 0. 999 7,0. 999 1,0. 999 8 and 0. 999 8. The average recoveries were 99. 17%( RSD = 0. 72%),97. 46%( RSD = 0. 85%),97. 91%( RSD = 1. 97%),98. 23%( RSD = 0. 82%)( n = 6). Conclusion: The method is accurate and can be used to evaluate the quality of NHJDT.
Key concepts: Baicalin, Emodin, Chromatography, Baicalein, Aloe emodin, Chemistry, High-performance liquid chromatography, Phosphoric acid