Research On AGC Optimization Control Strategy of Large Thermal Power Unit

Wei Jing

Open publisher page 2 citations

Abstract

The boiler main steam pressure in unit generator has large inertia and lag characteristic.Aiming at the characteristic of the controlled object,this paper applied the state variable technique and the phase compensating technique to the steam pressure control strategy,which was based on direct energy balance.The large inertia and lag characteristic of the controlled object can be compensated and load adaptive ability can be improved by using large-lag compensation technique.Furthermore,some measures had been taken to improve the control characteristic of the power unit.The simulation results have shown that this control strategy is effective.

About this research paper

What this paper is about

The boiler main steam pressure in unit generator has large inertia and lag characteristic.Aiming at the characteristic of the controlled object,this paper applied the state variable technique and the phase compensating technique to the steam pressure control strategy,which was based on direct energy balance.The large inertia and lag characteristic of the controlled object can be compensated and load adaptive ability can be improved by using large-lag compensation technique.Furthermore,some measures had been taken to improve the control characteristic of the power unit.The simulation results have shown that this control strategy is effective.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The boiler main steam pressure in unit generator has large inertia and lag characteristic.Aiming at the characteristic of the controlled object,this paper applied the state variable technique and the phase compensating technique to the steam pressure control strategy,which was based on direct energy balance.The large inertia and lag characteristic of the controlled object can be compensated and load adaptive ability can be improved by using large-lag compensation technique.Furthermore,some measures had been taken to improve the control characteristic of the power unit.The simulation results have shown that this control strategy is effective.

Key concepts: Control theory (sociology), Lag, Inertia, Boiler (water heating), Steam pressure, Unit load, Compensation (psychology), Thermal power station