2005Progress in Veterinary MedicineRequires access

Analysis of Electrocardiograms of Tibet Hog

YU Chen-lin, Yunzhong Liu, Zhaowei Chen, Wang Chunhua, Gu Wei-Wang, Zhang Jia-ning

Open publisher page 0 citations

Abstract

The analysis of electrocardiogram of Tibet hog is used to observe the developing process and compare with the electrocardiogram of human being and Guizhou miniature pig to provide basic data for Tibet hog's experimental animalization.Methods:45 Tibet hogs in conscious were traced fromⅠ,Ⅱ and Ⅲ standard leads and aVR、aVL and aVFunipolar extremity leads with electrocardiogram ECG-9020K.Result:①There was a sinus rhythm in all examined Tibet hogs.②All P waves were erect in Ⅰ,Ⅱ and aVF leads,but inverted in aVR lead,most of it were erect in Ⅲ and aVL leads.③The QRS complex form was qR in Ⅰ lead,qRs and Rs in Ⅱ lead,Rs and qRs in Ⅲ lead,qR、 rsr'and qr in aVL lead,rsr'、Qr and Q in aVR lead,Rs and qRs in aVF lead primarily.④Most of T wave were erect in Ⅰ,Ⅱ,Ⅲ and aVF leads,and inverted in aVL and aVR leads.⑤The duration of various waves and interval:P duration is 68.18 ms±(23.54 ms;)P-R interval is 92.69 ms±20.64 ms;QRS interval is 47.76 ms±13.50 ms;Q-T interval is(225.93) ms±45.03 ms;Q-Tc interval is 225.47 ms±31.23 ms.The character of Tibet hog's electrocardiogram is similar to human being's on the whole,except that its heart rate is faster,and P-R interval,QRS interval,S-T interval and Q-T interval are shorter,and it is similar to GuiZhou miniature pig extremely except that its Q-T interval is shorter.

About this research paper

What this paper is about

The analysis of electrocardiogram of Tibet hog is used to observe the developing process and compare with the electrocardiogram of human being and Guizhou miniature pig to provide basic data for Tibet hog's experimental animalization.Methods:45 Tibet hogs in conscious were traced fromⅠ,Ⅱ and Ⅲ standard leads and aVR、aVL and aVFunipolar extremity leads with electrocardiogram ECG-9020K.Result:①There was a sinus rhythm in all examined Tibet hogs.②All P waves were erect in Ⅰ,Ⅱ and aVF leads,but inverted in aVR lead,most of it were erect in Ⅲ and aVL leads.③The QRS complex form was qR in Ⅰ lead,qRs and Rs in Ⅱ lead,Rs and qRs in Ⅲ lead,qR、 rsr'and qr in aVL lead,rsr'、Qr and Q in aVR lead,Rs and qRs in aVF lead primarily.④Most of T wave were erect in Ⅰ,Ⅱ,Ⅲ and aVF leads,and inverted in aVL and aVR leads.⑤The duration of various waves and interval:P duration is 68.18 ms±(23.54 ms;)P-R interval is 92.69 ms±20.64 ms;QRS interval is 47.76 ms±13.50 ms;Q-T interval is(225.93) ms±45.03 ms;Q-Tc interval is 225.47 ms±31.23 ms.The character of Tibet hog's electrocardiogram is similar to human being's on the whole,except that its heart rate is faster,and P-R interval,QRS interval,S-T interval and Q-T interval are shorter,and it is similar to GuiZhou miniature pig extremely except that its Q-T interval is shorter.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The analysis of electrocardiogram of Tibet hog is used to observe the developing process and compare with the electrocardiogram of human being and Guizhou miniature pig to provide basic data for Tibet hog's experimental animalization.Methods:45 Tibet hogs in conscious were traced fromⅠ,Ⅱ and Ⅲ standard leads and aVR、aVL and aVFunipolar extremity leads with electrocardiogram ECG-9020K.Result:①There was a sinus rhythm in all examined Tibet hogs.②All P waves were erect in Ⅰ,Ⅱ and aVF leads,but inverted in aVR lead,most of it were erect in Ⅲ and aVL leads.③The QRS complex form was qR in Ⅰ lead,qRs and Rs in Ⅱ lead,Rs and qRs in Ⅲ lead,qR、 rsr'and qr in aVL lead,rsr'、Qr and Q in aVR lead,Rs and qRs in aVF lead primarily.④Most of T wave were erect in Ⅰ,Ⅱ,Ⅲ and aVF leads,and inverted in aVL and aVR leads.⑤The duration of various waves and interval:P duration is 68.18 ms±(23.54 ms;)P-R interval is 92.69 ms±20.64 ms;QRS interval is 47.76 ms±13.50 ms;Q-T interval is(225.93) ms±45.03 ms;Q-Tc interval is 225.47 ms±31.23 ms.The character of Tibet hog's electrocardiogram is similar to human being's on the whole,except that its heart rate is faster,and P-R interval,QRS interval,S-T interval and Q-T interval are shorter,and it is similar to GuiZhou miniature pig extremely except that its Q-T interval is shorter.

Key concepts: QRS complex, Normal Sinus Rhythm, PR interval, Cardiology, Interval (graph theory), QT interval, Lead (geology), Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of Electrocardiograms of Tibet Hog — Research Paper | ScholarLens