2014Unpublished venueRequires access

Diagnosis and Preventive Measures of Transformer Winding Deformation

Qin Zhixia

Open publisher page 0 citations

Abstract

In order to improve the diagnosis level of transformer winding deformation,and reduce or avoid the happening of transformer winding deformation accident,field test data of a certain transformer in different period are analyzed by using low voltage short circuit impedance method and frequency response method,and rules of transformer winding deformation are discussed. By combining above two methods,whether the deformation of transformer winding has happened or not can be diagnosed,and further more the winding of deformation and the degree of the deformation can be obtained. Preventive measures for the transformer winding deformation from aspects of test,protection and maintenance are proposed.

About this research paper

What this paper is about

In order to improve the diagnosis level of transformer winding deformation,and reduce or avoid the happening of transformer winding deformation accident,field test data of a certain transformer in different period are analyzed by using low voltage short circuit impedance method and frequency response method,and rules of transformer winding deformation are discussed. By combining above two methods,whether the deformation of transformer winding has happened or not can be diagnosed,and further more the winding of deformation and the degree of the deformation can be obtained. Preventive measures for the transformer winding deformation from aspects of test,protection and maintenance are proposed.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to improve the diagnosis level of transformer winding deformation,and reduce or avoid the happening of transformer winding deformation accident,field test data of a certain transformer in different period are analyzed by using low voltage short circuit impedance method and frequency response method,and rules of transformer winding deformation are discussed. By combining above two methods,whether the deformation of transformer winding has happened or not can be diagnosed,and further more the winding of deformation and the degree of the deformation can be obtained. Preventive measures for the transformer winding deformation from aspects of test,protection and maintenance are proposed.

Key concepts: Transformer, Rotary variable differential transformer, Leakage inductance, Delta-wye transformer, Deformation (meteorology), Engineering, Linear variable differential transformer, Structural engineering