2003•Chinese Journal of PharmaceuticalsRequires access

Determination of Residual Organic Solvents in Arbidol by Capillary GC

Kang Xue

Open publisher page 0 citations

Abstract

A capillary GC method with FID detector for determination of residual organic solvents——methanol, ethanol, acetone, ethyl ether and petroleum ether (60~90 ℃) in arbidol was established. An OV 101 capillary column (0.22 mm×30 m) was used with procedural column temperature control. Nitrogen gas was used as carrier gas. The detection limits were 5,5,3,3 and 10 ng, respectively. The calibration curves of the five solvents were linear ( r 0.997). The average recoveries were 99.4%, 101.6% ,101.1%,101.9% and 97.1%, respectively.

About this research paper

What this paper is about

A capillary GC method with FID detector for determination of residual organic solvents——methanol, ethanol, acetone, ethyl ether and petroleum ether (60~90 ℃) in arbidol was established. An OV 101 capillary column (0.22 mm×30 m) was used with procedural column temperature control. Nitrogen gas was used as carrier gas. The detection limits were 5,5,3,3 and 10 ng, respectively. The calibration curves of the five solvents were linear ( r 0.997). The average recoveries were 99.4%, 101.6% ,101.1%,101.9% and 97.1%, respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A capillary GC method with FID detector for determination of residual organic solvents——methanol, ethanol, acetone, ethyl ether and petroleum ether (60~90 ℃) in arbidol was established. An OV 101 capillary column (0.22 mm×30 m) was used with procedural column temperature control. Nitrogen gas was used as carrier gas. The detection limits were 5,5,3,3 and 10 ng, respectively. The calibration curves of the five solvents were linear ( r 0.997). The average recoveries were 99.4%, 101.6% ,101.1%,101.9% and 97.1%, respectively.

Key concepts: Chemistry, Acetone, Chromatography, Methanol, Capillary action, Gas chromatography, Calibration curve, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Residual Organic Solvents in Arbidol by Capillary GC — Research Paper | ScholarLens