2012Chinese Medical Equipment JournalRequires access

Individual Scanning for Multislice Spiral CT Coronary Angiography

Huan Yi

Open publisher page 0 citations

Abstract

Objective To evaluate a method to adjust scan parameters individually for reducing radiation dose of multislice CT coronary angiography.Methods There were 131 cases divided into conventional group(group A) and low dose group(group B) with 61 patients in group A and 70 patients in group B.Standard scan technique was used in group A and dose reduction techniques were employed in group B.Subsequently,group B were scanned with individually adjusted mA and kV according to BMI.CTDIvol,DLP,ED,SNR and CNR in the two groups were evaluated.Results The average age of both groups of patients,heart rate,scan length,height,weight and BMI were no differences(P0.05).The average CTDIvol in group A and group B was(40.7±6.7) mGy and(24.5±10.8) mGy,respectively.There was a statistical difference in CTDIvol between the two groups(t=10.1,P0.05).Effective dose(ED) was(9.5± 1.6) mSv,(5.5±2.6) mSv,respectively.There was a statistical difference in ED between the two groups(t =10.0,P0.05).The radiation dose of group B was lower by 45% than that of group A.SNR was 38.9±10.5 and 36.0±12.2 respectively,with t=1.5 and P0.05;CNR was 35.0±9.7and 32.2±11.0 respectively,with t=1.6 and P0.05;there were no differences in SNR and CNR between the two groups.Conclusion Adjusting scanning parameters according to body mass index and heart rate for multislice CT coronary angiography can reduce the radiation dose while having no influence on the quality of imaging.

About this research paper

What this paper is about

Objective To evaluate a method to adjust scan parameters individually for reducing radiation dose of multislice CT coronary angiography.Methods There were 131 cases divided into conventional group(group A) and low dose group(group B) with 61 patients in group A and 70 patients in group B.Standard scan technique was used in group A and dose reduction techniques were employed in group B.Subsequently,group B were scanned with individually adjusted mA and kV according to BMI.CTDIvol,DLP,ED,SNR and CNR in the two groups were evaluated.Results The average age of both groups of patients,heart rate,scan length,height,weight and BMI were no differences(P0.05).The average CTDIvol in group A and group B was(40.7±6.7) mGy and(24.5±10.8) mGy,respectively.There was a statistical difference in CTDIvol between the two groups(t=10.1,P0.05).Effective dose(ED) was(9.5± 1.6) mSv,(5.5±2.6) mSv,respectively.There was a statistical difference in ED between the two groups(t =10.0,P0.05).The radiation dose of group B was lower by 45% than that of group A.SNR was 38.9±10.5 and 36.0±12.2 respectively,with t=1.5 and P0.05;CNR was 35.0±9.7and 32.2±11.0 respectively,with t=1.6 and P0.05;there were no differences in SNR and CNR between the two groups.Conclusion Adjusting scanning parameters according to body mass index and heart rate for multislice CT coronary angiography can reduce the radiation dose while having no influence on the quality of imaging.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate a method to adjust scan parameters individually for reducing radiation dose of multislice CT coronary angiography.Methods There were 131 cases divided into conventional group(group A) and low dose group(group B) with 61 patients in group A and 70 patients in group B.Standard scan technique was used in group A and dose reduction techniques were employed in group B.Subsequently,group B were scanned with individually adjusted mA and kV according to BMI.CTDIvol,DLP,ED,SNR and CNR in the two groups were evaluated.Results The average age of both groups of patients,heart rate,scan length,height,weight and BMI were no differences(P0.05).The average CTDIvol in group A and group B was(40.7±6.7) mGy and(24.5±10.8) mGy,respectively.There was a statistical difference in CTDIvol between the two groups(t=10.1,P0.05).Effective dose(ED) was(9.5± 1.6) mSv,(5.5±2.6) mSv,respectively.There was a statistical difference in ED between the two groups(t =10.0,P0.05).The radiation dose of group B was lower by 45% than that of group A.SNR was 38.9±10.5 and 36.0±12.2 respectively,with t=1.5 and P0.05;CNR was 35.0±9.7and 32.2±11.0 respectively,with t=1.6 and P0.05;there were no differences in SNR and CNR between the two groups.Conclusion Adjusting scanning parameters according to body mass index and heart rate for multislice CT coronary angiography can reduce the radiation dose while having no influence on the quality of imaging.

Key concepts: Medicine, Nuclear medicine, Effective dose (radiation), Radiation dose, Coronary angiography, Group B, Statistical significance, Spiral (railway)

Related papers

Back to paper searchBrowse research topicsOriginal source
Individual Scanning for Multislice Spiral CT Coronary Angiography — Research Paper | ScholarLens