1983•Acta Chimica SinicaRequires access

POLAROGRAPHIC CATALYTIC WAVE OF COBALT ION IN PHENANTHROLINE-THIOUREA MEDIUM

Zhengchuang Zhao

Open publisher page 0 citations

Abstract

In 8×10~(-7) M phenanthroline-0.02M thiourea medium(ethanolamine buffer,pH 8.3), by using Na_2SO_3 to remove dissolved oxygen, cobaltion can produce a sensitive catalytio wave with a peak shape on d polarography. E_p=1.62V (vs. S. C. E. ), detection limit is 1×10~(-10)M. There is a linear dependence of peak height on cobalt concentration over a range of 2×10~(-10)~4×10~(-8)M. Common ions which are not more than 1000-fold of Co~(2+) do not interfere the determination of cobalt, except Ni~(2+) and As~(3+) which are permitted to only 125 and 300-fold respectively. Good results are obtained in determining traces of cobalt in various samples by this method.

About this research paper

What this paper is about

In 8×10~(-7) M phenanthroline-0.02M thiourea medium(ethanolamine buffer,pH 8.3), by using Na_2SO_3 to remove dissolved oxygen, cobaltion can produce a sensitive catalytio wave with a peak shape on d polarography. E_p=1.62V (vs. S. C. E. ), detection limit is 1×10~(-10)M. There is a linear dependence of peak height on cobalt concentration over a range of 2×10~(-10)~4×10~(-8)M. Common ions which are not more than 1000-fold of Co~(2+) do not interfere the determination of cobalt, except Ni~(2+) and As~(3+) which are permitted to only 125 and 300-fold respectively. Good results are obtained in determining traces of cobalt in various samples by this method.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In 8×10~(-7) M phenanthroline-0.02M thiourea medium(ethanolamine buffer,pH 8.3), by using Na_2SO_3 to remove dissolved oxygen, cobaltion can produce a sensitive catalytio wave with a peak shape on d polarography. E_p=1.62V (vs. S. C. E. ), detection limit is 1×10~(-10)M. There is a linear dependence of peak height on cobalt concentration over a range of 2×10~(-10)~4×10~(-8)M. Common ions which are not more than 1000-fold of Co~(2+) do not interfere the determination of cobalt, except Ni~(2+) and As~(3+) which are permitted to only 125 and 300-fold respectively. Good results are obtained in determining traces of cobalt in various samples by this method.

Key concepts: Polarography, Chemistry, Cobalt, Thiourea, Phenanthroline, Ethanolamine, Ion, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
POLAROGRAPHIC CATALYTIC WAVE OF COBALT ION IN PHENANTHROLINE-THIOUREA MEDIUM — Research Paper | ScholarLens