2009Journal of Beijing Union UniversityRequires access

Investigation on the Piezoelectrica Biosensing Real-time Response Characteristics of Biotin-streptavidin System

Zhu Li-hua

Open publisher page 0 citations

Abstract

There are strong affinity and high specificity between biotin and streptavidin.Biotin and streptavidin were used in piezoelectrica biosensing investigation,so the piezoelectrica biosensing real-time response characteristics of biotin-streptavidin system were reflected.Effects of pH on adsorption deeds of biotin and streptavidin,impacts of experiment condition on reaction of biotin and streptavidin including incubating time and concentration of streptavidin and reaction time,and reaction characteristics were discussed.It was demonstrated that the adsorption of streptavidin is the best after incubating 8 hours in concentration of 100 μg/mL when pH is 7.4.Under the optimal experimental condition,the frequency shift is linear with the biotin mass concentration in the range of 0.11~1.65 μg/mL.

About this research paper

What this paper is about

There are strong affinity and high specificity between biotin and streptavidin.Biotin and streptavidin were used in piezoelectrica biosensing investigation,so the piezoelectrica biosensing real-time response characteristics of biotin-streptavidin system were reflected.Effects of pH on adsorption deeds of biotin and streptavidin,impacts of experiment condition on reaction of biotin and streptavidin including incubating time and concentration of streptavidin and reaction time,and reaction characteristics were discussed.It was demonstrated that the adsorption of streptavidin is the best after incubating 8 hours in concentration of 100 μg/mL when pH is 7.4.Under the optimal experimental condition,the frequency shift is linear with the biotin mass concentration in the range of 0.11~1.65 μg/mL.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

There are strong affinity and high specificity between biotin and streptavidin.Biotin and streptavidin were used in piezoelectrica biosensing investigation,so the piezoelectrica biosensing real-time response characteristics of biotin-streptavidin system were reflected.Effects of pH on adsorption deeds of biotin and streptavidin,impacts of experiment condition on reaction of biotin and streptavidin including incubating time and concentration of streptavidin and reaction time,and reaction characteristics were discussed.It was demonstrated that the adsorption of streptavidin is the best after incubating 8 hours in concentration of 100 μg/mL when pH is 7.4.Under the optimal experimental condition,the frequency shift is linear with the biotin mass concentration in the range of 0.11~1.65 μg/mL.

Key concepts: Streptavidin, Biotin, Biosensor, Adsorption, Chemistry, Biotinylation, Chromatography, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Investigation on the Piezoelectrica Biosensing Real-time Response Characteristics of Biotin-streptavidin System — Research Paper | ScholarLens