2010Anhui nongye kexueRequires access

Study on the Degradation of Microcystins MC-LR with the Method of Fenton Oxidation

Dong ZeQin

Open publisher page 0 citations

Abstract

[Objective] The efficiency of the Fenton oxidation on the degradation of microcystins MC-LR in slightly polluted water was analyzed.[Method] The experiment in the effect of the Fenton oxidation on the degradation of MC-LR in slightly polluted water was conducted and the concentration of H2O2 and Fe2+-adding,the pH value,the initial concentration of microcystin,the reaction time and others affecting the degradation effect was measured.Meanwhile,the related factor related to the process of Fenton oxidation degrading MC-LR in water was also discussed.[Results] The optimal condition was the initial concentration of H2O2 was 0.30 mmol/L,the molar ratio of [H2O2]/[FeSO4] was 30∶1,the pH value was 4.0,the reaction temperature was(24±2)℃ and the reaction time was 60 minutes while the concentration of microcystin MC-LR was 0.31 mg/L,so that the removal rate of MC-LR was 90.30%.[Conclusion] The microcystin MC-LR could be effectively degraded through the Fenton Oxidation under certain condition.

About this research paper

What this paper is about

[Objective] The efficiency of the Fenton oxidation on the degradation of microcystins MC-LR in slightly polluted water was analyzed.[Method] The experiment in the effect of the Fenton oxidation on the degradation of MC-LR in slightly polluted water was conducted and the concentration of H2O2 and Fe2+-adding,the pH value,the initial concentration of microcystin,the reaction time and others affecting the degradation effect was measured.Meanwhile,the related factor related to the process of Fenton oxidation degrading MC-LR in water was also discussed.[Results] The optimal condition was the initial concentration of H2O2 was 0.30 mmol/L,the molar ratio of [H2O2]/[FeSO4] was 30∶1,the pH value was 4.0,the reaction temperature was(24±2)℃ and the reaction time was 60 minutes while the concentration of microcystin MC-LR was 0.31 mg/L,so that the removal rate of MC-LR was 90.30%.[Conclusion] The microcystin MC-LR could be effectively degraded through the Fenton Oxidation under certain condition.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective] The efficiency of the Fenton oxidation on the degradation of microcystins MC-LR in slightly polluted water was analyzed.[Method] The experiment in the effect of the Fenton oxidation on the degradation of MC-LR in slightly polluted water was conducted and the concentration of H2O2 and Fe2+-adding,the pH value,the initial concentration of microcystin,the reaction time and others affecting the degradation effect was measured.Meanwhile,the related factor related to the process of Fenton oxidation degrading MC-LR in water was also discussed.[Results] The optimal condition was the initial concentration of H2O2 was 0.30 mmol/L,the molar ratio of [H2O2]/[FeSO4] was 30∶1,the pH value was 4.0,the reaction temperature was(24±2)℃ and the reaction time was 60 minutes while the concentration of microcystin MC-LR was 0.31 mg/L,so that the removal rate of MC-LR was 90.30%.[Conclusion] The microcystin MC-LR could be effectively degraded through the Fenton Oxidation under certain condition.

Key concepts: Degradation (telecommunications), Microcystin-LR, Chemistry, Molar ratio, Environmental chemistry, Microcystin, Fenton reaction, Nuclear chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Degradation of Microcystins MC-LR with the Method of Fenton Oxidation — Research Paper | ScholarLens