2010PubMedRequires access

[Determination of cyanuric acid in milk and milk powder by high performance liquid chromatography-tandem mass spectrometry].

Qianwen Gui, Han Liu, Zengyun Zhao, Tao Ding, Jinzhong Xu, Weijian Shen, Chongyu Shen, Bin Wu, Rui Zhang

Open publisher page 0 citations

Abstract

A method for the determination of cyanuric acid (CYA) in milk and milk powder was developed using high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI MS/MS). The target analyte was extracted from samples by acetonitrile, and the proteins were precipitated at the same time. The supernatant was cleaned up and enriched with a strong anion exchange column, analysed by HPLC-MS/MS with an AX column, and quantified by internal standard method. Good linearity was obtained in the range of 50-2000 microg/L. The recoveries were all ranged from 97% to 121% at three levels, 200, 500 and 1000 microg/kg, and the relative standard deviations (RSDs) were all below 4.8%. Limit of quantification (LOQ) was 200 microg/kg. The method has high accuracy and precision, the operation is fast, easy and suitable for the determination of CYA in milk and milk powder.

About this research paper

What this paper is about

A method for the determination of cyanuric acid (CYA) in milk and milk powder was developed using high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI MS/MS). The target analyte was extracted from samples by acetonitrile, and the proteins were precipitated at the same time. The supernatant was cleaned up and enriched with a strong anion exchange column, analysed by HPLC-MS/MS with an AX column, and quantified by internal standard method. Good linearity was obtained in the range of 50-2000 microg/L. The recoveries were all ranged from 97% to 121% at three levels, 200, 500 and 1000 microg/kg, and the relative standard deviations (RSDs) were all below 4.8%. Limit of quantification (LOQ) was 200 microg/kg. The method has high accuracy and precision, the operation is fast, easy and suitable for the determination of CYA in milk and milk powder.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of cyanuric acid (CYA) in milk and milk powder was developed using high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI MS/MS). The target analyte was extracted from samples by acetonitrile, and the proteins were precipitated at the same time. The supernatant was cleaned up and enriched with a strong anion exchange column, analysed by HPLC-MS/MS with an AX column, and quantified by internal standard method. Good linearity was obtained in the range of 50-2000 microg/L. The recoveries were all ranged from 97% to 121% at three levels, 200, 500 and 1000 microg/kg, and the relative standard deviations (RSDs) were all below 4.8%. Limit of quantification (LOQ) was 200 microg/kg. The method has high accuracy and precision, the operation is fast, easy and suitable for the determination of CYA in milk and milk powder.

Key concepts: Chemistry, Chromatography, Cyanuric acid, Analyte, Detection limit, High-performance liquid chromatography, Mass spectrometry, Electrospray ionization

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of cyanuric acid in milk and milk powder by high performance liquid chromatography-tandem mass spectrometry]. — Research Paper | ScholarLens