2003Shiyong fangshexue zazhiRequires access

Quantitative Study of Diffusion Weighted Imaging of Magnetic Resonance Imaging in Hepatic Lesions

Tang Ming

Open publisher page 0 citations

Abstract

Objective To evaluate the characteristics of MR imaging of hepatic lesions by using measurement of ADC values on the DWI imaging.Methods MR diffusion-weighted images were performed in 127 patients with hepatic lesions, ADC values of lesions and the ratio of the ADC values of lesion/liver were calculated. Results Average ADC values of hepatic lesions were as follows: hepatocellular carcinoma(0.99±0.26)×10 -3 mm 2/s,hepatic metastase(1.17±0.32)×10 -3 mm 2/s,hepatic cavernous hemangioma(1.81±0.42)×10 -3 mm 2/s,hepatic cyst(3.11±0.38)×10 -3 mm 2/s, cirrhosis of liver(0.92±0.25)×10 -3 mm 2/s,fatty liver(1.37±0.32)×10 -3 mm 2/s. The ratio of the ADC values of lesion/liver in hepatocellular carcinoma and hepatic metastases was 0.89±0.17and 1.27±0.21 respectively,there were significant different between both.Conclusion The quantitative study in hepatic lesions using ADC value, the ratio of the ADC values of lesion/liver, would improve the accuracy in diagnosing hepatic lesions.

About this research paper

What this paper is about

Objective To evaluate the characteristics of MR imaging of hepatic lesions by using measurement of ADC values on the DWI imaging.Methods MR diffusion-weighted images were performed in 127 patients with hepatic lesions, ADC values of lesions and the ratio of the ADC values of lesion/liver were calculated. Results Average ADC values of hepatic lesions were as follows: hepatocellular carcinoma(0.99±0.26)×10 -3 mm 2/s,hepatic metastase(1.17±0.32)×10 -3 mm 2/s,hepatic cavernous hemangioma(1.81±0.42)×10 -3 mm 2/s,hepatic cyst(3.11±0.38)×10 -3 mm 2/s, cirrhosis of liver(0.92±0.25)×10 -3 mm 2/s,fatty liver(1.37±0.32)×10 -3 mm 2/s. The ratio of the ADC values of lesion/liver in hepatocellular carcinoma and hepatic metastases was 0.89±0.17and 1.27±0.21 respectively,there were significant different between both.Conclusion The quantitative study in hepatic lesions using ADC value, the ratio of the ADC values of lesion/liver, would improve the accuracy in diagnosing hepatic lesions.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the characteristics of MR imaging of hepatic lesions by using measurement of ADC values on the DWI imaging.Methods MR diffusion-weighted images were performed in 127 patients with hepatic lesions, ADC values of lesions and the ratio of the ADC values of lesion/liver were calculated. Results Average ADC values of hepatic lesions were as follows: hepatocellular carcinoma(0.99±0.26)×10 -3 mm 2/s,hepatic metastase(1.17±0.32)×10 -3 mm 2/s,hepatic cavernous hemangioma(1.81±0.42)×10 -3 mm 2/s,hepatic cyst(3.11±0.38)×10 -3 mm 2/s, cirrhosis of liver(0.92±0.25)×10 -3 mm 2/s,fatty liver(1.37±0.32)×10 -3 mm 2/s. The ratio of the ADC values of lesion/liver in hepatocellular carcinoma and hepatic metastases was 0.89±0.17and 1.27±0.21 respectively,there were significant different between both.Conclusion The quantitative study in hepatic lesions using ADC value, the ratio of the ADC values of lesion/liver, would improve the accuracy in diagnosing hepatic lesions.

Key concepts: Medicine, Hepatocellular carcinoma, Magnetic resonance imaging, Lesion, Cirrhosis, Effective diffusion coefficient, Diffusion MRI, Hemangioma

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantitative Study of Diffusion Weighted Imaging of Magnetic Resonance Imaging in Hepatic Lesions — Research Paper | ScholarLens