Objective: Observation serpentine endoscopic tracheal intubation,especially the effects of difficult airway intubation. Method: required general anesthesia for elective surgery patients,200 cases were randomly divided into two groups ( snake-like tube endoscopic intubation) ,comparison group ( direct laryngoscopy intubation) ,each of 100 cases. Were observed intubation time-consuming,test plug number,number of intubation complications. Results: the control group intubation-related complications occurred significantly more than the number of the observation group ( P 0. 05) . Class Ⅰ ~ Ⅱ in the glottis was observed under exposure group was significantly more than control group consuming intubation ( P 0. 05) ,wipe the number of occurrence of the number of intubation complications There was no significant difference ( P 0. 05) . Class Ⅲ ~ Ⅳ in the glottis was observed under exposure group intubation time-consuming,test plug number and the number of occurrence of intubation complications were significantly less than the control group ( P 0. 05) . Conclusion: Serpentine endoscopic intubation tube test plug can effectively reduce the number of difficult airway intubation to improve the success rate,reducing intubation time-consuming to reduce the intubation-related complications,is a solution of difficult airway intubation effective technology.

About this research paper

What this paper is about

Objective: Observation serpentine endoscopic tracheal intubation,especially the effects of difficult airway intubation. Method: required general anesthesia for elective surgery patients,200 cases were randomly divided into two groups ( snake-like tube endoscopic intubation) ,comparison group ( direct laryngoscopy intubation) ,each of 100 cases. Were observed intubation time-consuming,test plug number,number of intubation complications. Results: the control group intubation-related complications occurred significantly more than the number of the observation group ( P 0. 05) . Class Ⅰ ~ Ⅱ in the glottis was observed under exposure group was significantly more than control group consuming intubation ( P 0. 05) ,wipe the number of occurrence of the number of intubation complications There was no significant difference ( P 0. 05) . Class Ⅲ ~ Ⅳ in the glottis was observed under exposure group intubation time-consuming,test plug number and the number of occurrence of intubation complications were significantly less than the control group ( P 0. 05) . Conclusion: Serpentine endoscopic intubation tube test plug can effectively reduce the number of difficult airway intubation to improve the success rate,reducing intubation time-consuming to reduce the intubation-related complications,is a solution of difficult airway intubation effective technology.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: Observation serpentine endoscopic tracheal intubation,especially the effects of difficult airway intubation. Method: required general anesthesia for elective surgery patients,200 cases were randomly divided into two groups ( snake-like tube endoscopic intubation) ,comparison group ( direct laryngoscopy intubation) ,each of 100 cases. Were observed intubation time-consuming,test plug number,number of intubation complications. Results: the control group intubation-related complications occurred significantly more than the number of the observation group ( P 0. 05) . Class Ⅰ ~ Ⅱ in the glottis was observed under exposure group was significantly more than control group consuming intubation ( P 0. 05) ,wipe the number of occurrence of the number of intubation complications There was no significant difference ( P 0. 05) . Class Ⅲ ~ Ⅳ in the glottis was observed under exposure group intubation time-consuming,test plug number and the number of occurrence of intubation complications were significantly less than the control group ( P 0. 05) . Conclusion: Serpentine endoscopic intubation tube test plug can effectively reduce the number of difficult airway intubation to improve the success rate,reducing intubation time-consuming to reduce the intubation-related complications,is a solution of difficult airway intubation effective technology.

Key concepts: Intubation, Medicine, Glottis, Anesthesia, Airway, Laryngoscopy, Tracheal intubation, Elective surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Serpentine endoscopic airway intubation Effect — Research Paper | ScholarLens