HPLC determination of the content and related substances in irinotecan hydrochloride injection
Jia Jia
Abstract
Jia Jia
Abstract
Objective: To establish a method for determination of the content and related substances in irinotecan hydrochloride injections.Methods: HPLC was performed on a Suplex PKB-100 column with the mobile phase of phosphate buffer(Potassium dihydrogen phosphate 1.36 g and Octanesulfonic acid sodium 2.18 g,dissolved in water 1000 mL,and the pH adjusted to 3.5 using phosphoric acid)-methanol-acetonitrile(55∶ 25∶ 20)at a flow rate of 1.0mL·min-1;the column temperature was 30 ℃,and the detection wavelength was 254 nm.Results: The liner range of calibration curve for irinotecan hydrochloride was 0.0255-0.1788 mg·mL-1(r=0.9999),the RSD of precision was 0.04%(n =5),and the RSD of repeatability was 0.40%(n =6),the average recovery was 100.2%(RSD=0.9%,n =9);the sample solution has a good stability in 8 h,the limit of quantitation was 0.91 ng,the limit of detection was 0.27 ng.The repeatability and recovery of the known impurities were good.Conclusion: The established method is suitable for determination of the content and related substances in irinotecan hydrochloride injections.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: To establish a method for determination of the content and related substances in irinotecan hydrochloride injections.Methods: HPLC was performed on a Suplex PKB-100 column with the mobile phase of phosphate buffer(Potassium dihydrogen phosphate 1.36 g and Octanesulfonic acid sodium 2.18 g,dissolved in water 1000 mL,and the pH adjusted to 3.5 using phosphoric acid)-methanol-acetonitrile(55∶ 25∶ 20)at a flow rate of 1.0mL·min-1;the column temperature was 30 ℃,and the detection wavelength was 254 nm.Results: The liner range of calibration curve for irinotecan hydrochloride was 0.0255-0.1788 mg·mL-1(r=0.9999),the RSD of precision was 0.04%(n =5),and the RSD of repeatability was 0.40%(n =6),the average recovery was 100.2%(RSD=0.9%,n =9);the sample solution has a good stability in 8 h,the limit of quantitation was 0.91 ng,the limit of detection was 0.27 ng.The repeatability and recovery of the known impurities were good.Conclusion: The established method is suitable for determination of the content and related substances in irinotecan hydrochloride injections.
Key concepts: Chemistry, Chromatography, Repeatability, Phosphoric acid, High-performance liquid chromatography, Calibration curve, Detection limit, Potassium