2002Zhongguo linchuang jiepouxue zazhiRequires access

Axial anatomical evaluation of the posterior atlantoaxial transarticular screw fixation

Zhengjin Liu

Open publisher page 0 citations

Abstract

Objective: To provide morphological basis for the posterior atlantoixal transarticular screw fixation. Methods:The clinical significant data were measured on 100 dry axis specimens.Results:The pedicle width of 96.5% specimen was larger than 4.5 mm. In 11.5% specimens, the internal height of the lateral mass was smaller than 2.1 mm. The internal height of the pedicle was smaller than 4.5 mm in 20.6 % of all specimens, while 8.1% was at the right side and 12.5% was at the left side.The internal height of the pedicle was smaller than 4.5 mm in 15.7% male specimens and 10% female specimens.The axis of the screw fixation was found to lie at 39.2°±* 5.04° in the medical direction and 5. 79°± 2. 45° in the superior direction. Conclusion: 21. 5% Chinese are unsuitable for posterior atlantoaxial transarticular screw fixation.

About this research paper

What this paper is about

Objective: To provide morphological basis for the posterior atlantoixal transarticular screw fixation. Methods:The clinical significant data were measured on 100 dry axis specimens.Results:The pedicle width of 96.5% specimen was larger than 4.5 mm. In 11.5% specimens, the internal height of the lateral mass was smaller than 2.1 mm. The internal height of the pedicle was smaller than 4.5 mm in 20.6 % of all specimens, while 8.1% was at the right side and 12.5% was at the left side.The internal height of the pedicle was smaller than 4.5 mm in 15.7% male specimens and 10% female specimens.The axis of the screw fixation was found to lie at 39.2°±* 5.04° in the medical direction and 5. 79°± 2. 45° in the superior direction. Conclusion: 21. 5% Chinese are unsuitable for posterior atlantoaxial transarticular screw fixation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To provide morphological basis for the posterior atlantoixal transarticular screw fixation. Methods:The clinical significant data were measured on 100 dry axis specimens.Results:The pedicle width of 96.5% specimen was larger than 4.5 mm. In 11.5% specimens, the internal height of the lateral mass was smaller than 2.1 mm. The internal height of the pedicle was smaller than 4.5 mm in 20.6 % of all specimens, while 8.1% was at the right side and 12.5% was at the left side.The internal height of the pedicle was smaller than 4.5 mm in 15.7% male specimens and 10% female specimens.The axis of the screw fixation was found to lie at 39.2°±* 5.04° in the medical direction and 5. 79°± 2. 45° in the superior direction. Conclusion: 21. 5% Chinese are unsuitable for posterior atlantoaxial transarticular screw fixation.

Key concepts: Lateral mass, Internal fixation, Fixation (population genetics), Anatomy, Medicine, Orthodontics, Cervical spine, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Axial anatomical evaluation of the posterior atlantoaxial transarticular screw fixation — Research Paper | ScholarLens