2004•Chinese Journal of Veterinary DrugRequires access

Determination of oxytetracycline residues in milk by RP-HPLC

WU Xu-gang

Open publisher page 0 citations

Abstract

The method for determining oxytetracycline residues in milk by RP-HPLC was established. Oxytetracycline in milk was extracted by methanol with oxalic acid. After being centrifuged, the extract was assayed by HPLC with C_(18) column(5 μm,250 mm×4.6 mm) and methanol-acetonitrile - 0.01mol/L oxalic acid (20∶12∶68,(V/V)) as the mobile phase at flow rate of 1 mL/min. The detection wavelenght was at 360 nm. The standard curve was linear for oxytetracycline in the range of 50~1 500 μg/L(r=0.999 9,n=6). The average recovery(n=5) was 88%. The method is simple, accurate and rapid.

About this research paper

What this paper is about

The method for determining oxytetracycline residues in milk by RP-HPLC was established. Oxytetracycline in milk was extracted by methanol with oxalic acid. After being centrifuged, the extract was assayed by HPLC with C_(18) column(5 μm,250 mm×4.6 mm) and methanol-acetonitrile - 0.01mol/L oxalic acid (20∶12∶68,(V/V)) as the mobile phase at flow rate of 1 mL/min. The detection wavelenght was at 360 nm. The standard curve was linear for oxytetracycline in the range of 50~1 500 μg/L(r=0.999 9,n=6). The average recovery(n=5) was 88%. The method is simple, accurate and rapid.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The method for determining oxytetracycline residues in milk by RP-HPLC was established. Oxytetracycline in milk was extracted by methanol with oxalic acid. After being centrifuged, the extract was assayed by HPLC with C_(18) column(5 μm,250 mm×4.6 mm) and methanol-acetonitrile - 0.01mol/L oxalic acid (20∶12∶68,(V/V)) as the mobile phase at flow rate of 1 mL/min. The detection wavelenght was at 360 nm. The standard curve was linear for oxytetracycline in the range of 50~1 500 μg/L(r=0.999 9,n=6). The average recovery(n=5) was 88%. The method is simple, accurate and rapid.

Key concepts: Oxytetracycline, High-performance liquid chromatography, Chromatography, Chemistry, Oxalic acid, Methanol, Acetonitrile, Antibiotics

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of oxytetracycline residues in milk by RP-HPLC — Research Paper | ScholarLens