2003Physical Testing and Chemical AnalysisRequires access

FI-CHEMILUMINESCENCE DETERMINATION OF HYDROQUINONE

Liqing Li, Yanmei Zhou, LU Jiu-ru

Open publisher page 0 citations

Abstract

The chemiluminescence behavior of the oxidation reaction of hydroquinone (HQN) by potassium permanganate was studied under the condition of flow-injection. The intensity of chemiluminescence was found to be in linear relationship with the concentration of hydroquinone in the range of 2.0×10 -7 to 8.0×10 -5 g·ml -1 . The precision was tested at the concentration level of 4.0×10 -6 g·ml -1 for 11 determinations and the value of RSD obtained was 1.5%. This proposed method has been used satisfactorily in the determination of hydroquinone in waste water.

About this research paper

What this paper is about

The chemiluminescence behavior of the oxidation reaction of hydroquinone (HQN) by potassium permanganate was studied under the condition of flow-injection. The intensity of chemiluminescence was found to be in linear relationship with the concentration of hydroquinone in the range of 2.0×10 -7 to 8.0×10 -5 g·ml -1 . The precision was tested at the concentration level of 4.0×10 -6 g·ml -1 for 11 determinations and the value of RSD obtained was 1.5%. This proposed method has been used satisfactorily in the determination of hydroquinone in waste water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The chemiluminescence behavior of the oxidation reaction of hydroquinone (HQN) by potassium permanganate was studied under the condition of flow-injection. The intensity of chemiluminescence was found to be in linear relationship with the concentration of hydroquinone in the range of 2.0×10 -7 to 8.0×10 -5 g·ml -1 . The precision was tested at the concentration level of 4.0×10 -6 g·ml -1 for 11 determinations and the value of RSD obtained was 1.5%. This proposed method has been used satisfactorily in the determination of hydroquinone in waste water.

Key concepts: Chemiluminescence, Hydroquinone, Potassium permanganate, Chemistry, Permanganate, Linear range, Linear relationship, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
FI-CHEMILUMINESCENCE DETERMINATION OF HYDROQUINONE — Research Paper | ScholarLens