2008CHINESE JOURNAL OF ANALYTICAL CHEMISTRY (CHINESE VERSION)Requires access

Determination of Arsenic by Atomic Fluorescence Spectrometry with Bi-anode Electrochemical Hydride Generation

Shen Tu

Open publisher page 0 citations

Abstract

Determination of arsenic by atomic fluorescence spectrometry with bi-anode electrochemical hydride generation(BAECHG)was investigated.This novel method reduced the use of chemical reagents and thus reduced environmental pollution because no chemical hydride generation procedure was used.Under the same conditions,the hydride generation efficiency of BAECHG was 99.0%-101.6% of that of chemical hydride generation method.Parameters and interference conditions were investigated.Under the selected conditions,the linear range was 0-120 μg/L for arsenic(As,injection volume: 100 μL).The detection limit(signal to noise ratio of 3∶1) was 0.64 μg/L.The relative standard deviation(RSD) obtained by using standard solution with 60 μg/L of As was 2.0%(n=13).The proposed method was applied to analyze the reference soil sample(GBW07406),the result was consistent with the certified value.The spiked recoveries of piglet feed sample were 97.0%-103.0%.High sensitivity and good repeatibility are the advantages of this method.

About this research paper

What this paper is about

Determination of arsenic by atomic fluorescence spectrometry with bi-anode electrochemical hydride generation(BAECHG)was investigated.This novel method reduced the use of chemical reagents and thus reduced environmental pollution because no chemical hydride generation procedure was used.Under the same conditions,the hydride generation efficiency of BAECHG was 99.0%-101.6% of that of chemical hydride generation method.Parameters and interference conditions were investigated.Under the selected conditions,the linear range was 0-120 μg/L for arsenic(As,injection volume: 100 μL).The detection limit(signal to noise ratio of 3∶1) was 0.64 μg/L.The relative standard deviation(RSD) obtained by using standard solution with 60 μg/L of As was 2.0%(n=13).The proposed method was applied to analyze the reference soil sample(GBW07406),the result was consistent with the certified value.The spiked recoveries of piglet feed sample were 97.0%-103.0%.High sensitivity and good repeatibility are the advantages of this method.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Determination of arsenic by atomic fluorescence spectrometry with bi-anode electrochemical hydride generation(BAECHG)was investigated.This novel method reduced the use of chemical reagents and thus reduced environmental pollution because no chemical hydride generation procedure was used.Under the same conditions,the hydride generation efficiency of BAECHG was 99.0%-101.6% of that of chemical hydride generation method.Parameters and interference conditions were investigated.Under the selected conditions,the linear range was 0-120 μg/L for arsenic(As,injection volume: 100 μL).The detection limit(signal to noise ratio of 3∶1) was 0.64 μg/L.The relative standard deviation(RSD) obtained by using standard solution with 60 μg/L of As was 2.0%(n=13).The proposed method was applied to analyze the reference soil sample(GBW07406),the result was consistent with the certified value.The spiked recoveries of piglet feed sample were 97.0%-103.0%.High sensitivity and good repeatibility are the advantages of this method.

Key concepts: Chemistry, Hydride, Detection limit, Arsenic, Reagent, Certified reference materials, Analytical Chemistry (journal), Anode

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Arsenic by Atomic Fluorescence Spectrometry with Bi-anode Electrochemical Hydride Generation — Research Paper | ScholarLens