Gas Chromatography Tandem Triple Quadrupole Mass Spectrometric Determination of Cyanuric Acid and Melamine in Milk Powder
Chunjuan Li
Abstract
Chunjuan Li
Abstract
A gas chromatography tandem triple quadrupole mass spectrometric(GC-QqQ-MS/MS) method was presented for the determination of cyanuric acid and melamine in milk powder.Samples were extracted with methanol and derivatized with a mixed system composed of BSTFA and TMCS(99:1,V/V) prior to GC-QqQ-MS/MS analysis in multiple reaction monitoring(MRM) mode.The optimal values of crucial instrument parameters and matrix effects were investigated.Cyanuric acid was qualified using the ion pairs of m/z 345 215 and m/z 345 330 and quantified using the ion pair of m/z 345 215.Melamine was qualified using the ion pairs of m/z 345 171 and m/z 342 327 and quantified using the ion pair of m/z 342 327.The developed method exhibited good linearity within the range of 0.010 to 0.500 mg/L.Limit of detection was 0.016 for cyanuric acid and 0.003 mg/kg for melamine(RSN =3).Precision RSDs for determining cyanuric acid and melamine were within the ranges of 4.5%-8.6% and 3.9%-6.2%,respectively.Recoveries of cyanuric acid and melamine in an infant formula milk power sample spiked at two levels were ranged from 84.0% to 102.0% and from 88.5% to 104.0%,respectively.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A gas chromatography tandem triple quadrupole mass spectrometric(GC-QqQ-MS/MS) method was presented for the determination of cyanuric acid and melamine in milk powder.Samples were extracted with methanol and derivatized with a mixed system composed of BSTFA and TMCS(99:1,V/V) prior to GC-QqQ-MS/MS analysis in multiple reaction monitoring(MRM) mode.The optimal values of crucial instrument parameters and matrix effects were investigated.Cyanuric acid was qualified using the ion pairs of m/z 345 215 and m/z 345 330 and quantified using the ion pair of m/z 345 215.Melamine was qualified using the ion pairs of m/z 345 171 and m/z 342 327 and quantified using the ion pair of m/z 342 327.The developed method exhibited good linearity within the range of 0.010 to 0.500 mg/L.Limit of detection was 0.016 for cyanuric acid and 0.003 mg/kg for melamine(RSN =3).Precision RSDs for determining cyanuric acid and melamine were within the ranges of 4.5%-8.6% and 3.9%-6.2%,respectively.Recoveries of cyanuric acid and melamine in an infant formula milk power sample spiked at two levels were ranged from 84.0% to 102.0% and from 88.5% to 104.0%,respectively.
Key concepts: Cyanuric acid, Melamine, Chemistry, Chromatography, Detection limit, Triple quadrupole mass spectrometer, Selected reaction monitoring, Mass spectrometry