2009Journal of Sun Yat-sen UniversityRequires access

Value of Contrast-enhanced Ultrasound in Diagnosis of Focal liver lesions

Zhao Xian

Open publisher page 0 citations

Abstract

【Objective】The focal liver lesions are one of the major challenges in imaging diagnosis. The purpose of this article was to investigate the value of real-time contrast-enhanced ultrasound (CEUS) in the diagnosis of focal liver lesions. 【Methods】 68 patients with 87 focal liver lesions were diagnosed with CEUS and baseline ultrasound simultaneously. The CEUS features were studied, including predominant enhancement phases, arrival time of contrast agent, enhancement peak time, enhancement patterns and regression time of contrast agent. The final diagnosis was confirmed by pathological evidences. 【Results】 Using the pathological results as gold standard, there were 38 cases of malignant focal liver lesions, including 19 hepatocellular carcinomas, 14 metastatic hepatic carcinomas, 3 intrahepatic cholangiocarcinoma, 1 hepatoblastoma, 1 malignant lymphadenoma, and there were 49 benign focal liver lesions, including 20 hemangiomas, 5 focal nodular hyperplasias (FNHs), 7 hyperplastic nodules and 15 focal fatty sparings (FFSs). The sensitivity, specificity, and accuracy of CEUS were 88.6%, 89.9%, and 76.8%, respectively. While the baseline ultrasound were 67.6%, 63.8%, and 59.4%, respectively. 【Conclusion】Real-time CEUS is an effective imaging modality in diagnosis of the focal liver lesions.

About this research paper

What this paper is about

【Objective】The focal liver lesions are one of the major challenges in imaging diagnosis. The purpose of this article was to investigate the value of real-time contrast-enhanced ultrasound (CEUS) in the diagnosis of focal liver lesions. 【Methods】 68 patients with 87 focal liver lesions were diagnosed with CEUS and baseline ultrasound simultaneously. The CEUS features were studied, including predominant enhancement phases, arrival time of contrast agent, enhancement peak time, enhancement patterns and regression time of contrast agent. The final diagnosis was confirmed by pathological evidences. 【Results】 Using the pathological results as gold standard, there were 38 cases of malignant focal liver lesions, including 19 hepatocellular carcinomas, 14 metastatic hepatic carcinomas, 3 intrahepatic cholangiocarcinoma, 1 hepatoblastoma, 1 malignant lymphadenoma, and there were 49 benign focal liver lesions, including 20 hemangiomas, 5 focal nodular hyperplasias (FNHs), 7 hyperplastic nodules and 15 focal fatty sparings (FFSs). The sensitivity, specificity, and accuracy of CEUS were 88.6%, 89.9%, and 76.8%, respectively. While the baseline ultrasound were 67.6%, 63.8%, and 59.4%, respectively. 【Conclusion】Real-time CEUS is an effective imaging modality in diagnosis of the focal liver lesions.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

【Objective】The focal liver lesions are one of the major challenges in imaging diagnosis. The purpose of this article was to investigate the value of real-time contrast-enhanced ultrasound (CEUS) in the diagnosis of focal liver lesions. 【Methods】 68 patients with 87 focal liver lesions were diagnosed with CEUS and baseline ultrasound simultaneously. The CEUS features were studied, including predominant enhancement phases, arrival time of contrast agent, enhancement peak time, enhancement patterns and regression time of contrast agent. The final diagnosis was confirmed by pathological evidences. 【Results】 Using the pathological results as gold standard, there were 38 cases of malignant focal liver lesions, including 19 hepatocellular carcinomas, 14 metastatic hepatic carcinomas, 3 intrahepatic cholangiocarcinoma, 1 hepatoblastoma, 1 malignant lymphadenoma, and there were 49 benign focal liver lesions, including 20 hemangiomas, 5 focal nodular hyperplasias (FNHs), 7 hyperplastic nodules and 15 focal fatty sparings (FFSs). The sensitivity, specificity, and accuracy of CEUS were 88.6%, 89.9%, and 76.8%, respectively. While the baseline ultrasound were 67.6%, 63.8%, and 59.4%, respectively. 【Conclusion】Real-time CEUS is an effective imaging modality in diagnosis of the focal liver lesions.

Key concepts: Contrast-enhanced ultrasound, Medicine, Hepatoblastoma, Focal nodular hyperplasia, Ultrasound, Hepatocellular carcinoma, Radiology, Pathological

Related papers

Back to paper searchBrowse research topicsOriginal source
Value of Contrast-enhanced Ultrasound in Diagnosis of Focal liver lesions — Research Paper | ScholarLens