2014•The Orthopedic Journal of ChinaRequires access

Efficacy of third-generation absorbable rods in the treatment of Mason type II-IV radial head fractures in adults

LI Xiao-don

Open publisher page 0 citations

Abstract

[Objective]To explore the methods,feasibility,and clinical efficacy of third- generation absorbable rods in the treatment of Mason type Ⅱ- IV radial head fractures in adults.[Method]From August 2010 to March 2013,80 patients from our hospital with a radial head fracture were enrolled. The radial head was revealed through a small incision on the outer elbow.Third- generation absorbable rods( diameter 2 mm) were used to cross fix the radial head fracture. The patient participated in functional exercise 3- 4 weeks after cast immobilization. Radiographs were reviewed during the regular follow- up,and the patient's functional status was evaluated according to Metaizeau elbow score standards. The clinical efficacy of different types of radial head fractures was compared.[Result]The wound healing rate was 100%. The postoperative follow- up duration was 1- 3years( average,1. 7 ± 0. 5 years). Based on Metaizeau elbow score standards,among 28 cases of Mason type Ⅱ radial head fractures,the score was excellent in 20,good in 8,medium in 0,and poor in 0 patients; among 41 cases of Mason type Ⅲ radial head fractures,the score was excellent in 17,good in 13,medium in 1,and poor in 0 patients; among 11 cases of Mason type Ⅲradial head fractures,the score was excellent in 1,good in 7,medium in 2,and poor in 1 patient. The use of third- generation absorbable rods demonstrated the best result in Mason typeⅡ radial head fractures,followed by Mason type Ⅲ,and the worst result in Mason type Ⅳ fractures. One patient with Mason type Ⅲ radial head fracture required a second surgery due to complications.[Conclusion]The use of third- generation absorbable rods in the treatment of Mason type Ⅱ- IV radial head fractures requires a simple surgical technique with a hidden incision,lesser trauma,and fewer complications. Its use helps avoid fixator removal surgery and thereby reduces patient suffering,which is considered a worthy cause in clinical practice.

About this research paper

What this paper is about

[Objective]To explore the methods,feasibility,and clinical efficacy of third- generation absorbable rods in the treatment of Mason type Ⅱ- IV radial head fractures in adults.[Method]From August 2010 to March 2013,80 patients from our hospital with a radial head fracture were enrolled. The radial head was revealed through a small incision on the outer elbow.Third- generation absorbable rods( diameter 2 mm) were used to cross fix the radial head fracture. The patient participated in functional exercise 3- 4 weeks after cast immobilization. Radiographs were reviewed during the regular follow- up,and the patient's functional status was evaluated according to Metaizeau elbow score standards. The clinical efficacy of different types of radial head fractures was compared.[Result]The wound healing rate was 100%. The postoperative follow- up duration was 1- 3years( average,1. 7 ± 0. 5 years). Based on Metaizeau elbow score standards,among 28 cases of Mason type Ⅱ radial head fractures,the score was excellent in 20,good in 8,medium in 0,and poor in 0 patients; among 41 cases of Mason type Ⅲ radial head fractures,the score was excellent in 17,good in 13,medium in 1,and poor in 0 patients; among 11 cases of Mason type Ⅲradial head fractures,the score was excellent in 1,good in 7,medium in 2,and poor in 1 patient. The use of third- generation absorbable rods demonstrated the best result in Mason typeⅡ radial head fractures,followed by Mason type Ⅲ,and the worst result in Mason type Ⅳ fractures. One patient with Mason type Ⅲ radial head fracture required a second surgery due to complications.[Conclusion]The use of third- generation absorbable rods in the treatment of Mason type Ⅱ- IV radial head fractures requires a simple surgical technique with a hidden incision,lesser trauma,and fewer complications. Its use helps avoid fixator removal surgery and thereby reduces patient suffering,which is considered a worthy cause in clinical practice.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective]To explore the methods,feasibility,and clinical efficacy of third- generation absorbable rods in the treatment of Mason type Ⅱ- IV radial head fractures in adults.[Method]From August 2010 to March 2013,80 patients from our hospital with a radial head fracture were enrolled. The radial head was revealed through a small incision on the outer elbow.Third- generation absorbable rods( diameter 2 mm) were used to cross fix the radial head fracture. The patient participated in functional exercise 3- 4 weeks after cast immobilization. Radiographs were reviewed during the regular follow- up,and the patient's functional status was evaluated according to Metaizeau elbow score standards. The clinical efficacy of different types of radial head fractures was compared.[Result]The wound healing rate was 100%. The postoperative follow- up duration was 1- 3years( average,1. 7 ± 0. 5 years). Based on Metaizeau elbow score standards,among 28 cases of Mason type Ⅱ radial head fractures,the score was excellent in 20,good in 8,medium in 0,and poor in 0 patients; among 41 cases of Mason type Ⅲ radial head fractures,the score was excellent in 17,good in 13,medium in 1,and poor in 0 patients; among 11 cases of Mason type Ⅲradial head fractures,the score was excellent in 1,good in 7,medium in 2,and poor in 1 patient. The use of third- generation absorbable rods demonstrated the best result in Mason typeⅡ radial head fractures,followed by Mason type Ⅲ,and the worst result in Mason type Ⅳ fractures. One patient with Mason type Ⅲ radial head fracture required a second surgery due to complications.[Conclusion]The use of third- generation absorbable rods in the treatment of Mason type Ⅱ- IV radial head fractures requires a simple surgical technique with a hidden incision,lesser trauma,and fewer complications. Its use helps avoid fixator removal surgery and thereby reduces patient suffering,which is considered a worthy cause in clinical practice.

Key concepts: Medicine, Radial head, Elbow, Radial head fracture, Surgery, Radiography, Orthodontics

Related papers

Back to paper searchBrowse research topicsOriginal source
Efficacy of third-generation absorbable rods in the treatment of Mason type II-IV radial head fractures in adults — Research Paper | ScholarLens