2008•Journal of Instrumental AnalysisRequires access

Simultaneous Determination of Ten Sulfonamides Residues in Milk by LC-MS/MS Method

Yan Long-bao

Open publisher page 0 citations

Abstract

A LC-MS /MS method was developed for the determination of ten sulfonamides residues in milk.The MS was operated in the positive ion mode using multiple reaction monitoring.The protein of the sample was separated by acetonitrile.The extract was concentrated under the stream of nitrogen.The analytes were separated on a reversed-phase column of ZORBAX SB-C18(5 μm,4.6 mm×150 mm i.d.) by using methanol-acetonitrile-0.2% formic acid 10 mmol/L ammonium acetate solution as the mobile phase and gradient elution.The limits of detection were 0.5 and 1.0 μg/L,respectively,and the recoveries were between 91% and 102%.

About this research paper

What this paper is about

A LC-MS /MS method was developed for the determination of ten sulfonamides residues in milk.The MS was operated in the positive ion mode using multiple reaction monitoring.The protein of the sample was separated by acetonitrile.The extract was concentrated under the stream of nitrogen.The analytes were separated on a reversed-phase column of ZORBAX SB-C18(5 μm,4.6 mm×150 mm i.d.) by using methanol-acetonitrile-0.2% formic acid 10 mmol/L ammonium acetate solution as the mobile phase and gradient elution.The limits of detection were 0.5 and 1.0 μg/L,respectively,and the recoveries were between 91% and 102%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A LC-MS /MS method was developed for the determination of ten sulfonamides residues in milk.The MS was operated in the positive ion mode using multiple reaction monitoring.The protein of the sample was separated by acetonitrile.The extract was concentrated under the stream of nitrogen.The analytes were separated on a reversed-phase column of ZORBAX SB-C18(5 μm,4.6 mm×150 mm i.d.) by using methanol-acetonitrile-0.2% formic acid 10 mmol/L ammonium acetate solution as the mobile phase and gradient elution.The limits of detection were 0.5 and 1.0 μg/L,respectively,and the recoveries were between 91% and 102%.

Key concepts: Chemistry, Chromatography, Formic acid, Ammonium acetate, Acetonitrile, Analyte, Elution, Methanol

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Determination of Ten Sulfonamides Residues in Milk by LC-MS/MS Method — Research Paper | ScholarLens