2008Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and AtomsRequires access

Measurement of Neutron Spectrum Parameters of Miniature Neutron Source Reactor

Fu Hongyu

Open publisher page 0 citations

Abstract

The neutron spectrum parameters of the miniature neutron source reactor(MNSR) in China Institute of Atomic Energy were measured by bare monitor method using Au,Zr and Fe as monitors.The measured values of α(a parameter accounting for the non-ideality of the 1/E epithermal neutron fluence rate distribution),f(thermal / epithermal neutron fluence rate) and fF(thermal / fast neutron fluence rate) in the inner irradiation site are-0.007±0.003,20.8±0.4,and 5.5±0.2,respectively.The value of φth measured by this method is agreed with that measured by 4πβ-γ method within 2%.Compared with SLOWPOKE,MNSR had higher values of α and fF.The com-parison with the previous measurements indicates that MNSR has a quite constant neutron spectrum.The fluence rate monitors are not needed when k0-NAA is performed by using MNSR as neutron source,and with occasional check,the comparator data from one measurement may be used as a standard for subsequent analyses over a period of time.

About this research paper

What this paper is about

The neutron spectrum parameters of the miniature neutron source reactor(MNSR) in China Institute of Atomic Energy were measured by bare monitor method using Au,Zr and Fe as monitors.The measured values of α(a parameter accounting for the non-ideality of the 1/E epithermal neutron fluence rate distribution),f(thermal / epithermal neutron fluence rate) and fF(thermal / fast neutron fluence rate) in the inner irradiation site are-0.007±0.003,20.8±0.4,and 5.5±0.2,respectively.The value of φth measured by this method is agreed with that measured by 4πβ-γ method within 2%.Compared with SLOWPOKE,MNSR had higher values of α and fF.The com-parison with the previous measurements indicates that MNSR has a quite constant neutron spectrum.The fluence rate monitors are not needed when k0-NAA is performed by using MNSR as neutron source,and with occasional check,the comparator data from one measurement may be used as a standard for subsequent analyses over a period of time.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The neutron spectrum parameters of the miniature neutron source reactor(MNSR) in China Institute of Atomic Energy were measured by bare monitor method using Au,Zr and Fe as monitors.The measured values of α(a parameter accounting for the non-ideality of the 1/E epithermal neutron fluence rate distribution),f(thermal / epithermal neutron fluence rate) and fF(thermal / fast neutron fluence rate) in the inner irradiation site are-0.007±0.003,20.8±0.4,and 5.5±0.2,respectively.The value of φth measured by this method is agreed with that measured by 4πβ-γ method within 2%.Compared with SLOWPOKE,MNSR had higher values of α and fF.The com-parison with the previous measurements indicates that MNSR has a quite constant neutron spectrum.The fluence rate monitors are not needed when k0-NAA is performed by using MNSR as neutron source,and with occasional check,the comparator data from one measurement may be used as a standard for subsequent analyses over a period of time.

Key concepts: Neutron source, Neutron temperature, Neutron flux, Neutron, Neutron cross section, Fluence, Irradiation, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement of Neutron Spectrum Parameters of Miniature Neutron Source Reactor — Research Paper | ScholarLens