2012Guangdong Electric PowerRequires access

High Frequency Transformer Design for Half Bridge LLC Type Resonant Converter

Xiangwu Yan

Open publisher page 0 citations

Abstract

As a key component of half bridge LLC resonant converter,high frequency transformer design may affect loss,stability of output voltage and heat value of switch power supply.Therefore,this paper aims at design for 5 kW high frequency transformer,introduces type selection principles for high frequency transformer cores and takes area product method to determine types of winding wires and cores.By further optimization calculation it gets numbers of windings,transformer loss and other relevant parameters.Final high frequency transformer parameters include that type of former vice side winding wire is No.18,type of core is EE-100,transformer ratio is 0.7375,former vice side winding numbers are 59 and 80 respectively and transformer loss is 16.187 W.

About this research paper

What this paper is about

As a key component of half bridge LLC resonant converter,high frequency transformer design may affect loss,stability of output voltage and heat value of switch power supply.Therefore,this paper aims at design for 5 kW high frequency transformer,introduces type selection principles for high frequency transformer cores and takes area product method to determine types of winding wires and cores.By further optimization calculation it gets numbers of windings,transformer loss and other relevant parameters.Final high frequency transformer parameters include that type of former vice side winding wire is No.18,type of core is EE-100,transformer ratio is 0.7375,former vice side winding numbers are 59 and 80 respectively and transformer loss is 16.187 W.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

As a key component of half bridge LLC resonant converter,high frequency transformer design may affect loss,stability of output voltage and heat value of switch power supply.Therefore,this paper aims at design for 5 kW high frequency transformer,introduces type selection principles for high frequency transformer cores and takes area product method to determine types of winding wires and cores.By further optimization calculation it gets numbers of windings,transformer loss and other relevant parameters.Final high frequency transformer parameters include that type of former vice side winding wire is No.18,type of core is EE-100,transformer ratio is 0.7375,former vice side winding numbers are 59 and 80 respectively and transformer loss is 16.187 W.