2009•Chinese Journal of Neurosurgical Disease ResearchRequires access

Clinical value of 16-row multislice CTA in the treatment of cerebral aneurysms

Qiu Jian-guo

Open publisher page 0 citations

Abstract

Objective To assess the clinical value of 16-row multislice CTA in the treatment of cerebral aneurysms.Methods A total of 186 cerebral aneurysms of 175 cases received 16-slice CTA. Using maximum-intensity projections and volume-rendering techniques,the shape,size and location of the aneurysms were defined.Results Fifty-two aneurysms were clipped on the basis of 16-slice CTA images. One hundred and thirty-four aneurysms received endovascular coiling based on information provided by CTA,such as shape,dimension andlocation of the aneurysms,the parent artery and the ratio of sac to neck,which could assist in finding the projection angle and deciding the necessity of stent implantation.Conclusion Sixteen-slice CTA is fast and relatively noninvasive and provides sufficient diagnostic information to guide neurosurgical and endovascular treatment of intracranial aneurysms.

About this research paper

What this paper is about

Objective To assess the clinical value of 16-row multislice CTA in the treatment of cerebral aneurysms.Methods A total of 186 cerebral aneurysms of 175 cases received 16-slice CTA. Using maximum-intensity projections and volume-rendering techniques,the shape,size and location of the aneurysms were defined.Results Fifty-two aneurysms were clipped on the basis of 16-slice CTA images. One hundred and thirty-four aneurysms received endovascular coiling based on information provided by CTA,such as shape,dimension andlocation of the aneurysms,the parent artery and the ratio of sac to neck,which could assist in finding the projection angle and deciding the necessity of stent implantation.Conclusion Sixteen-slice CTA is fast and relatively noninvasive and provides sufficient diagnostic information to guide neurosurgical and endovascular treatment of intracranial aneurysms.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To assess the clinical value of 16-row multislice CTA in the treatment of cerebral aneurysms.Methods A total of 186 cerebral aneurysms of 175 cases received 16-slice CTA. Using maximum-intensity projections and volume-rendering techniques,the shape,size and location of the aneurysms were defined.Results Fifty-two aneurysms were clipped on the basis of 16-slice CTA images. One hundred and thirty-four aneurysms received endovascular coiling based on information provided by CTA,such as shape,dimension andlocation of the aneurysms,the parent artery and the ratio of sac to neck,which could assist in finding the projection angle and deciding the necessity of stent implantation.Conclusion Sixteen-slice CTA is fast and relatively noninvasive and provides sufficient diagnostic information to guide neurosurgical and endovascular treatment of intracranial aneurysms.

Key concepts: Medicine, Radiology, Maximum intensity projection, Multislice, Endovascular treatment, Aneurysm, Volume rendering, Stent

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinical value of 16-row multislice CTA in the treatment of cerebral aneurysms — Research Paper | ScholarLens