2010•Physical Testing and Chemical AnalysisRequires access

GC Determination of Residual Amounts of Nitrobenzenes in Water with Capillary Chromatographic Column

HE Li-zhi

Open publisher page 0 citations

Abstract

Gas chromatography with capillary column(HP-5) was applied to the determination of residual amounts of nitrobenzenes in water.The sample was extracted with benzene and the extract was used for GC analysis with electron capture detector.Ten nitrobenzenes were separated satisfactorily and determined within 28 min. Values of detection limit(2S/N) and RSD's(n=7) of 10 nitrobenzene compounds found were in the ranges of 1.0×10~(-3)-7.0×10~(-2)μg·L~(-1) and 1.5%-1.5%respectively.The proposed method was used in determinations of nitrobenzene compounds in samples of surface water and waste water,giving values of recovery ranged from 80.2%to 104.5%.

About this research paper

What this paper is about

Gas chromatography with capillary column(HP-5) was applied to the determination of residual amounts of nitrobenzenes in water.The sample was extracted with benzene and the extract was used for GC analysis with electron capture detector.Ten nitrobenzenes were separated satisfactorily and determined within 28 min. Values of detection limit(2S/N) and RSD's(n=7) of 10 nitrobenzene compounds found were in the ranges of 1.0×10~(-3)-7.0×10~(-2)μg·L~(-1) and 1.5%-1.5%respectively.The proposed method was used in determinations of nitrobenzene compounds in samples of surface water and waste water,giving values of recovery ranged from 80.2%to 104.5%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Gas chromatography with capillary column(HP-5) was applied to the determination of residual amounts of nitrobenzenes in water.The sample was extracted with benzene and the extract was used for GC analysis with electron capture detector.Ten nitrobenzenes were separated satisfactorily and determined within 28 min. Values of detection limit(2S/N) and RSD's(n=7) of 10 nitrobenzene compounds found were in the ranges of 1.0×10~(-3)-7.0×10~(-2)μg·L~(-1) and 1.5%-1.5%respectively.The proposed method was used in determinations of nitrobenzene compounds in samples of surface water and waste water,giving values of recovery ranged from 80.2%to 104.5%.

Key concepts: Nitrobenzene, Chromatography, Chemistry, Electron capture detector, Detection limit, Gas chromatography, Benzene, Capillary gas chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
GC Determination of Residual Amounts of Nitrobenzenes in Water with Capillary Chromatographic Column — Research Paper | ScholarLens