2011•Physical Testing and Chemical AnalysisRequires access

ICP-AES Determination of Impurity Elements in Liquid Titanium Tetrachloride

Yong Cheng

Open publisher page 0 citations

Abstract

A new method for the determination of impurity elements,including Si,Al,V,Cr,Cu and Fe in liquid titanium tetrachloride by ICP-AES was proposed in this paper.Under the optimum experimental conditions of the ICP instrument,the matrix effect was eliminated by addition of mixed or individual standard solutions of the elements determined to the sample matrix,and the spectral interferences was eliminated by selecting suitable analytical spectral lines.Detection limits(3s) of the method were found to be in the range of 0.001-0.015 mg·L-1.

About this research paper

What this paper is about

A new method for the determination of impurity elements,including Si,Al,V,Cr,Cu and Fe in liquid titanium tetrachloride by ICP-AES was proposed in this paper.Under the optimum experimental conditions of the ICP instrument,the matrix effect was eliminated by addition of mixed or individual standard solutions of the elements determined to the sample matrix,and the spectral interferences was eliminated by selecting suitable analytical spectral lines.Detection limits(3s) of the method were found to be in the range of 0.001-0.015 mg·L-1.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method for the determination of impurity elements,including Si,Al,V,Cr,Cu and Fe in liquid titanium tetrachloride by ICP-AES was proposed in this paper.Under the optimum experimental conditions of the ICP instrument,the matrix effect was eliminated by addition of mixed or individual standard solutions of the elements determined to the sample matrix,and the spectral interferences was eliminated by selecting suitable analytical spectral lines.Detection limits(3s) of the method were found to be in the range of 0.001-0.015 mg·L-1.

Key concepts: Impurity, Titanium tetrachloride, Titanium, Matrix (chemical analysis), Inductively coupled plasma atomic emission spectroscopy, Analytical Chemistry (journal), Materials science, Standard addition

Related papers

Back to paper searchBrowse research topicsOriginal source
ICP-AES Determination of Impurity Elements in Liquid Titanium Tetrachloride — Research Paper | ScholarLens