Simultaneous Determination of Five Anti-epileptic Drugs in Human Plasma by HPLC
YI Li-xi
Abstract
YI Li-xi
Abstract
Objective To establish a method for simultaneous determination of 5 anti-epileptic drugs in human plasma by high performance liquid chromatography( HPLC). Methods The analysis was performed with an Agilent Eclipse XDB-C18analytical column( 4. 6 mm × 150 mm,5μm) by gradient elution of water and methanol. The flow rate was 1 mL·min- 1. The detection wavelengths were set at 210 nm during 0 to 10 min and 230 nm during 10. 01 to 15 min. Results The linear ranges of diazepam,clonazepam,carbamazepine,phenytoin sodium and phenobarbital were 0. 1- 20. 0μg · mL- 1,0. 01-10. 0 μg·mL- 1,0. 2-40μg·mL- 1,2-40μg·mL- 1and 2- 80 μg·mL- 1,respectively. All the calibration curves showed good linearity( r≥0. 997 4) in the concentration ranges. The RSD of intra-and inter-day of the 5 analytes was less than 15%,and the recoveries were 74. 4%- 91. 3%. Conclusion The developed HPLC assay is accurate,sensitive and reliable,and it can be readily utilized as a reference method for rapid clinical determination.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To establish a method for simultaneous determination of 5 anti-epileptic drugs in human plasma by high performance liquid chromatography( HPLC). Methods The analysis was performed with an Agilent Eclipse XDB-C18analytical column( 4. 6 mm × 150 mm,5μm) by gradient elution of water and methanol. The flow rate was 1 mL·min- 1. The detection wavelengths were set at 210 nm during 0 to 10 min and 230 nm during 10. 01 to 15 min. Results The linear ranges of diazepam,clonazepam,carbamazepine,phenytoin sodium and phenobarbital were 0. 1- 20. 0μg · mL- 1,0. 01-10. 0 μg·mL- 1,0. 2-40μg·mL- 1,2-40μg·mL- 1and 2- 80 μg·mL- 1,respectively. All the calibration curves showed good linearity( r≥0. 997 4) in the concentration ranges. The RSD of intra-and inter-day of the 5 analytes was less than 15%,and the recoveries were 74. 4%- 91. 3%. Conclusion The developed HPLC assay is accurate,sensitive and reliable,and it can be readily utilized as a reference method for rapid clinical determination.
Key concepts: Chromatography, Chemistry, High-performance liquid chromatography, Carbamazepine, Clonazepam, Calibration curve, Analyte, Human plasma