Determination of chromium and silicon in nickel-based brazing material by inductively coupled plasma atomic emission spectrometry
Yang Li
Abstract
Yang Li
Abstract
The analysis conditions of chromium and silicon in nickel-based brazing material by inductively coupled plasma atomic emission spectrometry(ICP-AES)were discussed.After the nickelbased brazing material was dissolved with aqua regia-hydrofluoric acid mixed acid,and matrix effect was reduced by matrix matching,chromium and silicon in the sample were determined by ICP-AES with spectral line of 267.716(125)nm and 251.612(133)nm as the analytical lines for chromium and silicon respectively.This proposed method was applied to the determination of chromium and silicon in actual samples and the results were consistent with those obtained by ammonium persulfate oxidization titration method and perchloric acid dehydration method.The relative standard deviation(RSD,n =6)of chromium and silicon was 0.55%-0.73% and 0.71%-1.0%,respectively.The recoveries were 100%-101%and 99%-100%,respectively.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The analysis conditions of chromium and silicon in nickel-based brazing material by inductively coupled plasma atomic emission spectrometry(ICP-AES)were discussed.After the nickelbased brazing material was dissolved with aqua regia-hydrofluoric acid mixed acid,and matrix effect was reduced by matrix matching,chromium and silicon in the sample were determined by ICP-AES with spectral line of 267.716(125)nm and 251.612(133)nm as the analytical lines for chromium and silicon respectively.This proposed method was applied to the determination of chromium and silicon in actual samples and the results were consistent with those obtained by ammonium persulfate oxidization titration method and perchloric acid dehydration method.The relative standard deviation(RSD,n =6)of chromium and silicon was 0.55%-0.73% and 0.71%-1.0%,respectively.The recoveries were 100%-101%and 99%-100%,respectively.
Key concepts: Chromium, Inductively coupled plasma, Silicon, Hydrofluoric acid, Aqua regia, Analytical Chemistry (journal), Chemistry, Inductively coupled plasma atomic emission spectroscopy