2013•Metallurgical AnalysisRequires access

Determination of chromium and silicon in nickel-based brazing material by inductively coupled plasma atomic emission spectrometry

Yang Li

Open publisher page 0 citations

Abstract

The analysis conditions of chromium and silicon in nickel-based brazing material by inductively coupled plasma atomic emission spectrometry(ICP-AES)were discussed.After the nickelbased brazing material was dissolved with aqua regia-hydrofluoric acid mixed acid,and matrix effect was reduced by matrix matching,chromium and silicon in the sample were determined by ICP-AES with spectral line of 267.716(125)nm and 251.612(133)nm as the analytical lines for chromium and silicon respectively.This proposed method was applied to the determination of chromium and silicon in actual samples and the results were consistent with those obtained by ammonium persulfate oxidization titration method and perchloric acid dehydration method.The relative standard deviation(RSD,n =6)of chromium and silicon was 0.55%-0.73% and 0.71%-1.0%,respectively.The recoveries were 100%-101%and 99%-100%,respectively.

About this research paper

What this paper is about

The analysis conditions of chromium and silicon in nickel-based brazing material by inductively coupled plasma atomic emission spectrometry(ICP-AES)were discussed.After the nickelbased brazing material was dissolved with aqua regia-hydrofluoric acid mixed acid,and matrix effect was reduced by matrix matching,chromium and silicon in the sample were determined by ICP-AES with spectral line of 267.716(125)nm and 251.612(133)nm as the analytical lines for chromium and silicon respectively.This proposed method was applied to the determination of chromium and silicon in actual samples and the results were consistent with those obtained by ammonium persulfate oxidization titration method and perchloric acid dehydration method.The relative standard deviation(RSD,n =6)of chromium and silicon was 0.55%-0.73% and 0.71%-1.0%,respectively.The recoveries were 100%-101%and 99%-100%,respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The analysis conditions of chromium and silicon in nickel-based brazing material by inductively coupled plasma atomic emission spectrometry(ICP-AES)were discussed.After the nickelbased brazing material was dissolved with aqua regia-hydrofluoric acid mixed acid,and matrix effect was reduced by matrix matching,chromium and silicon in the sample were determined by ICP-AES with spectral line of 267.716(125)nm and 251.612(133)nm as the analytical lines for chromium and silicon respectively.This proposed method was applied to the determination of chromium and silicon in actual samples and the results were consistent with those obtained by ammonium persulfate oxidization titration method and perchloric acid dehydration method.The relative standard deviation(RSD,n =6)of chromium and silicon was 0.55%-0.73% and 0.71%-1.0%,respectively.The recoveries were 100%-101%and 99%-100%,respectively.

Key concepts: Chromium, Inductively coupled plasma, Silicon, Hydrofluoric acid, Aqua regia, Analytical Chemistry (journal), Chemistry, Inductively coupled plasma atomic emission spectroscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of chromium and silicon in nickel-based brazing material by inductively coupled plasma atomic emission spectrometry — Research Paper | ScholarLens