Objective To discuss the clinical application of comprehensive radiation protection measures in interventional radiology.Methods By a combination use of bed lead rubber curtain,moveable lead glass shield,protective clothing,lead collar,lead glasses and exposure distance,interventional procedures were performed in 84 patients.The X-ray radiation dose of the operators was monitored by FJ- 2000.The results were statistically analyzed.Results The radiation doses estimated before and after the use of lead rubber curtains,lead glass shield,and lead protective clothing were(67.91±73.45)μSv vs. (4.47±10.37)μSv,(56.46±41.23)μSv vs.(3.68±6.46)μSv and(5.2±8.81)μSv vs.(0.61±1.36) |xSv,respectively,and the protective efficiency were 93.4%,93.5%and 88.4%,respectively.The differences were statistically significant(P 0.01).The radiation doses at the spots 1 m,2 m,and 3 m from the tube were(1.91±2.12)μSv,(0.79±1.92)μSv and(0.26±1.01)μSv,respectively.The attenuations of radiation dose at the spots 1 m and 3 m from the tube were 58.6%and 86.4%,respectively. The differences in radiation dose between the distance 1 m and 2 m,as well as between the distance 2 m and 3 m,were statistically significant(P 0.01).Conclusion The use of comprehensive protective measures can effectively reduce the radiation dose to the operators attending the interventional procedures.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To discuss the clinical application of comprehensive radiation protection measures in interventional radiology.Methods By a combination use of bed lead rubber curtain,moveable lead glass shield,protective clothing,lead collar,lead glasses and exposure distance,interventional procedures were performed in 84 patients.The X-ray radiation dose of the operators was monitored by FJ- 2000.The results were statistically analyzed.Results The radiation doses estimated before and after the use of lead rubber curtains,lead glass shield,and lead protective clothing were(67.91±73.45)μSv vs. (4.47±10.37)μSv,(56.46±41.23)μSv vs.(3.68±6.46)μSv and(5.2±8.81)μSv vs.(0.61±1.36) |xSv,respectively,and the protective efficiency were 93.4%,93.5%and 88.4%,respectively.The differences were statistically significant(P 0.01).The radiation doses at the spots 1 m,2 m,and 3 m from the tube were(1.91±2.12)μSv,(0.79±1.92)μSv and(0.26±1.01)μSv,respectively.The attenuations of radiation dose at the spots 1 m and 3 m from the tube were 58.6%and 86.4%,respectively. The differences in radiation dose between the distance 1 m and 2 m,as well as between the distance 2 m and 3 m,were statistically significant(P 0.01).Conclusion The use of comprehensive protective measures can effectively reduce the radiation dose to the operators attending the interventional procedures.
Key concepts: Medicine, Radiation protection, Nuclear medicine, Lead apron, Lead (geology), Radiation exposure, Radiation dose, Interventional radiology