Comparison of Three Linear Current Control Strategies for Grid-connected Inverters
Jianhui Su
Abstract
Jianhui Su
Abstract
Three typical linear current control strategies for grid-connected inverters are compared.Firstly,the structure and characteristics of linear current control strategies with three different reference frames are introduced.Then with spectrum shift theory,the essential of dq synchronous reference frame control is revealed,and its equivalent structure under αβ stationary reference frame is derived.Besides,concern on the steady-state errors,dynamic response and grid disturbance rejection,the performance of three different linear current control strategies are compared theoretically.Finally,the simulation results with MATLAB are presented.Theoretical analysis and simulation prove that the performance of dq synchronous reference frame control and αβ stationary reference frame control are much better than abc natural reference frame control,whereas the dynamic performance of the three are similar.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Three typical linear current control strategies for grid-connected inverters are compared.Firstly,the structure and characteristics of linear current control strategies with three different reference frames are introduced.Then with spectrum shift theory,the essential of dq synchronous reference frame control is revealed,and its equivalent structure under αβ stationary reference frame is derived.Besides,concern on the steady-state errors,dynamic response and grid disturbance rejection,the performance of three different linear current control strategies are compared theoretically.Finally,the simulation results with MATLAB are presented.Theoretical analysis and simulation prove that the performance of dq synchronous reference frame control and αβ stationary reference frame control are much better than abc natural reference frame control,whereas the dynamic performance of the three are similar.
Key concepts: Reference frame, Rotating reference frame, Control theory (sociology), Frame (networking), Grid, MATLAB, Computer science, Frame of reference