2008Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and AtomsRequires access

Calibration of Relative Detection Efficiency for Neutron Long Counter

Lin Mei

Open publisher page 0 citations

Abstract

The relative detection efficiency of neutron long counter was calibrated with 241Am-Be neutron source.Energy conversion coefficient between 5.1 MeV and 14 MeV was also determined by the associated particle method.At the same time,the relative detection efficiency and energy conversion coefficient were calculated with Monte-Carlo method.In present work,the uncertainty of relative detection efficiency from experiment and calculation is 10.8% and 2.3%,respectively.Both are coincident in the range of uncertainty.

About this research paper

What this paper is about

The relative detection efficiency of neutron long counter was calibrated with 241Am-Be neutron source.Energy conversion coefficient between 5.1 MeV and 14 MeV was also determined by the associated particle method.At the same time,the relative detection efficiency and energy conversion coefficient were calculated with Monte-Carlo method.In present work,the uncertainty of relative detection efficiency from experiment and calculation is 10.8% and 2.3%,respectively.Both are coincident in the range of uncertainty.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The relative detection efficiency of neutron long counter was calibrated with 241Am-Be neutron source.Energy conversion coefficient between 5.1 MeV and 14 MeV was also determined by the associated particle method.At the same time,the relative detection efficiency and energy conversion coefficient were calculated with Monte-Carlo method.In present work,the uncertainty of relative detection efficiency from experiment and calculation is 10.8% and 2.3%,respectively.Both are coincident in the range of uncertainty.

Key concepts: Calibration, Monte Carlo method, Neutron, Efficiency, Range (aeronautics), Neutron detection, Neutron source, Neutron temperature

Related papers

Back to paper searchBrowse research topicsOriginal source
Calibration of Relative Detection Efficiency for Neutron Long Counter — Research Paper | ScholarLens