2012•Nuclear TechniquesRequires access

Registered error between PET and CT images confirmed by a water model

Mingwu Fan

Open publisher page 1 citations

Abstract

The registered error between PET and CT imaging system was confirmed by a water model simulating clinical cases.A barrel of 6750 mL was filled with 59.2 MBq [18F]-FDG and scanned after 80 min by 2 dimension model PET/CT.The CT images were used to attenuate the PET images.The CT/PET images were obtained by image morphological processing analyses without barrel wall.The relationship of the water image centroids of CT and PET images was established by linear regression analysis,and the registered error between PET and CT image could be computed one slice by one slice.The alignment program was done 4 times following the protocol given by GE Healthcare.Compared with centroids of water CT images,centroids of PET images were shifted to X-axis(0.011slice+0.63) mm,to Y-axis(0.022×slice+1.35) mm.To match CT images,PET images should be translated along X-axis(2.69±0.15) mm,Y-axis(0.43±0.11) mm,Z-axis(0.86±0.23) mm,and X-axis be rotated by(0.06±0.07),Y-axis by(0.01±0.08),and Z-axis by(0.11±0.07).So,the systematic registered error was not affected by load and its distribution.By finding the registered error between PET and CT images for coordinate rotation random error,the water model could confirm the registered results of PET-CT system corrected by Alignment parameters.

About this research paper

What this paper is about

The registered error between PET and CT imaging system was confirmed by a water model simulating clinical cases.A barrel of 6750 mL was filled with 59.2 MBq [18F]-FDG and scanned after 80 min by 2 dimension model PET/CT.The CT images were used to attenuate the PET images.The CT/PET images were obtained by image morphological processing analyses without barrel wall.The relationship of the water image centroids of CT and PET images was established by linear regression analysis,and the registered error between PET and CT image could be computed one slice by one slice.The alignment program was done 4 times following the protocol given by GE Healthcare.Compared with centroids of water CT images,centroids of PET images were shifted to X-axis(0.011slice+0.63) mm,to Y-axis(0.022×slice+1.35) mm.To match CT images,PET images should be translated along X-axis(2.69±0.15) mm,Y-axis(0.43±0.11) mm,Z-axis(0.86±0.23) mm,and X-axis be rotated by(0.06±0.07),Y-axis by(0.01±0.08),and Z-axis by(0.11±0.07).So,the systematic registered error was not affected by load and its distribution.By finding the registered error between PET and CT images for coordinate rotation random error,the water model could confirm the registered results of PET-CT system corrected by Alignment parameters.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The registered error between PET and CT imaging system was confirmed by a water model simulating clinical cases.A barrel of 6750 mL was filled with 59.2 MBq [18F]-FDG and scanned after 80 min by 2 dimension model PET/CT.The CT images were used to attenuate the PET images.The CT/PET images were obtained by image morphological processing analyses without barrel wall.The relationship of the water image centroids of CT and PET images was established by linear regression analysis,and the registered error between PET and CT image could be computed one slice by one slice.The alignment program was done 4 times following the protocol given by GE Healthcare.Compared with centroids of water CT images,centroids of PET images were shifted to X-axis(0.011slice+0.63) mm,to Y-axis(0.022×slice+1.35) mm.To match CT images,PET images should be translated along X-axis(2.69±0.15) mm,Y-axis(0.43±0.11) mm,Z-axis(0.86±0.23) mm,and X-axis be rotated by(0.06±0.07),Y-axis by(0.01±0.08),and Z-axis by(0.11±0.07).So,the systematic registered error was not affected by load and its distribution.By finding the registered error between PET and CT images for coordinate rotation random error,the water model could confirm the registered results of PET-CT system corrected by Alignment parameters.

Key concepts: Centroid, Nuclear medicine, Image registration, PET-CT, Tomography, Long axis, Materials science, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Registered error between PET and CT images confirmed by a water model — Research Paper | ScholarLens