2012•Xi'an Gongcheng Keji Xueyuan xuebaoRequires access

The impact of the tubular indirect evaporative cooler length on the cooling effect

Bai Yan-bin

Open publisher page 0 citations

Abstract

The tube length which influences the cooling effect of the indirect evaporative cooler has been analyzed by theoretical analysis and experiment test.The indirect evaporative cooler which tube length is 1m and 1.5m has been tested.According to the test results,the wet bulb efficiency of this evaporative cooler is calculated.It is shown that the better wet bulb efficiency is 55.6%.But compared to the heat exchange tube length of 1.5m tubular indirect evaporative cooler,there are about 10.4% lower in the efficiency.Therefore,the application of the 1.5m tube length indirect evaporative cooler should be take into account first.

About this research paper

What this paper is about

The tube length which influences the cooling effect of the indirect evaporative cooler has been analyzed by theoretical analysis and experiment test.The indirect evaporative cooler which tube length is 1m and 1.5m has been tested.According to the test results,the wet bulb efficiency of this evaporative cooler is calculated.It is shown that the better wet bulb efficiency is 55.6%.But compared to the heat exchange tube length of 1.5m tubular indirect evaporative cooler,there are about 10.4% lower in the efficiency.Therefore,the application of the 1.5m tube length indirect evaporative cooler should be take into account first.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The tube length which influences the cooling effect of the indirect evaporative cooler has been analyzed by theoretical analysis and experiment test.The indirect evaporative cooler which tube length is 1m and 1.5m has been tested.According to the test results,the wet bulb efficiency of this evaporative cooler is calculated.It is shown that the better wet bulb efficiency is 55.6%.But compared to the heat exchange tube length of 1.5m tubular indirect evaporative cooler,there are about 10.4% lower in the efficiency.Therefore,the application of the 1.5m tube length indirect evaporative cooler should be take into account first.

Key concepts: Evaporative cooler, Tube (container), Wet-bulb temperature, Mechanics, Thermodynamics, Chemistry, Environmental science, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
The impact of the tubular indirect evaporative cooler length on the cooling effect — Research Paper | ScholarLens