Measuring the harmonic current and power factor of nonlinear load

Liu Yan-xia

Open publisher page 0 citations

Abstract

Two methods are used to analyze harmonic current of typical signal-phase nonlinear load,the waveform of load current is presented with a cosine pulse function formula,the real power is gotten by integral operation,then the virtual values of 10 odd harmonic components of the current are measured with harmonic wave analyzer,the total distortion rate of harmonic wave of the load current is calculated.The results show that the generalized power factor of load is the product of displacement power factor and distortion power factor.The difference between traditional power factor and the generalized power factor is pointed out,and the influence of harmonic wave distortion rate on generalized power factor is discussed.

About this research paper

What this paper is about

Two methods are used to analyze harmonic current of typical signal-phase nonlinear load,the waveform of load current is presented with a cosine pulse function formula,the real power is gotten by integral operation,then the virtual values of 10 odd harmonic components of the current are measured with harmonic wave analyzer,the total distortion rate of harmonic wave of the load current is calculated.The results show that the generalized power factor of load is the product of displacement power factor and distortion power factor.The difference between traditional power factor and the generalized power factor is pointed out,and the influence of harmonic wave distortion rate on generalized power factor is discussed.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Two methods are used to analyze harmonic current of typical signal-phase nonlinear load,the waveform of load current is presented with a cosine pulse function formula,the real power is gotten by integral operation,then the virtual values of 10 odd harmonic components of the current are measured with harmonic wave analyzer,the total distortion rate of harmonic wave of the load current is calculated.The results show that the generalized power factor of load is the product of displacement power factor and distortion power factor.The difference between traditional power factor and the generalized power factor is pointed out,and the influence of harmonic wave distortion rate on generalized power factor is discussed.

Key concepts: Power factor, Harmonic, Total harmonic distortion, Non-sinusoidal waveform, Harmonics, Power (physics), Distortion (music), Waveform