2001Chinese Journal of Spectroscopy LaboratoryRequires access

Study on the Affection Factors of Luminol's Electrochemiluminescence System

Yi Tu, Zhu Ya

Open publisher page 0 citations

Abstract

The electrochemiluminescence(ECL) behaviour of luminol was systematically studied.It is obviously influenced by the electric parameters and acidity of the solution. The optimal ECL signal of luminol was occurred in the alkali medium (pH=12.5) and excited by the right orthogon pulse with the amplitude of 1.3V(vs. Ag/AgCl) on the Pt electrode.In the range of 1.0×10~-7- 1.0×10~-5 mol/L, the luminous intensities of ECL are linear correlation to the concentration of luminol. Furthermore, the affections of H_2O_2 and thiourea on the ECL of luminol were also studied.

About this research paper

What this paper is about

The electrochemiluminescence(ECL) behaviour of luminol was systematically studied.It is obviously influenced by the electric parameters and acidity of the solution. The optimal ECL signal of luminol was occurred in the alkali medium (pH=12.5) and excited by the right orthogon pulse with the amplitude of 1.3V(vs. Ag/AgCl) on the Pt electrode.In the range of 1.0×10~-7- 1.0×10~-5 mol/L, the luminous intensities of ECL are linear correlation to the concentration of luminol. Furthermore, the affections of H_2O_2 and thiourea on the ECL of luminol were also studied.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The electrochemiluminescence(ECL) behaviour of luminol was systematically studied.It is obviously influenced by the electric parameters and acidity of the solution. The optimal ECL signal of luminol was occurred in the alkali medium (pH=12.5) and excited by the right orthogon pulse with the amplitude of 1.3V(vs. Ag/AgCl) on the Pt electrode.In the range of 1.0×10~-7- 1.0×10~-5 mol/L, the luminous intensities of ECL are linear correlation to the concentration of luminol. Furthermore, the affections of H_2O_2 and thiourea on the ECL of luminol were also studied.

Key concepts: Luminol, Electrochemiluminescence, Chemiluminescence, Chemistry, Excited state, Analytical Chemistry (journal), Photochemistry, Inorganic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Affection Factors of Luminol's Electrochemiluminescence System — Research Paper | ScholarLens