2013•Journal of Changchun University of Science and TechnologyRequires access

No Card Data Acquisition Method Based on Labview

Zhang Li-jua

Open publisher page 0 citations

Abstract

When using Labview for data acquisition and control,we usually need to use the NI company special data acquisition card,however,which is very expensive. And developing our own data acquisition card is very difficult to resolve compatibility issues with Labview. To resolve this problem,in this paper a Labview data acquisition system design based on the shared memory is proposed. The method enables the reading and writing process to use the same physical memory. And the shared Buffer queue length can be adjusted dynamically according to the specific circumstances of the communication between the current process;ultimately the most rapid transmission of data with minimal memory consumption is achieved. Experimental results show that the system has a maximum data acquisition rate of17.5MB/s,which meets the data acquisition system data requirements and reasonable use of resources. This method can replace a dedicated data acquisition card when acquisition rate is not very high demands.

About this research paper

What this paper is about

When using Labview for data acquisition and control,we usually need to use the NI company special data acquisition card,however,which is very expensive. And developing our own data acquisition card is very difficult to resolve compatibility issues with Labview. To resolve this problem,in this paper a Labview data acquisition system design based on the shared memory is proposed. The method enables the reading and writing process to use the same physical memory. And the shared Buffer queue length can be adjusted dynamically according to the specific circumstances of the communication between the current process;ultimately the most rapid transmission of data with minimal memory consumption is achieved. Experimental results show that the system has a maximum data acquisition rate of17.5MB/s,which meets the data acquisition system data requirements and reasonable use of resources. This method can replace a dedicated data acquisition card when acquisition rate is not very high demands.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

When using Labview for data acquisition and control,we usually need to use the NI company special data acquisition card,however,which is very expensive. And developing our own data acquisition card is very difficult to resolve compatibility issues with Labview. To resolve this problem,in this paper a Labview data acquisition system design based on the shared memory is proposed. The method enables the reading and writing process to use the same physical memory. And the shared Buffer queue length can be adjusted dynamically according to the specific circumstances of the communication between the current process;ultimately the most rapid transmission of data with minimal memory consumption is achieved. Experimental results show that the system has a maximum data acquisition rate of17.5MB/s,which meets the data acquisition system data requirements and reasonable use of resources. This method can replace a dedicated data acquisition card when acquisition rate is not very high demands.

Key concepts: Data acquisition, Computer science, Computer hardware, Process (computing), Embedded system, Operating system

Related papers

Back to paper searchBrowse research topicsOriginal source
No Card Data Acquisition Method Based on Labview — Research Paper | ScholarLens