2014Zhiye yu jiankangRequires access

Uncertainty evaluation in determination of cadmium in rice by graphite furnace atomic absorption spectrometry

Yue Yun-ya

Open publisher page 1 citations

Abstract

[Objective]To analyze the whole determination process of cadmium in rice by graphite furnace atomic absorption spectrometry,study the influencing factors of uncertainty,and evaluate the uncertainty.[Methods]The content of cadmium in rice was detected by graphite furnace atomic absorption spectrometry according to the method of GB /T 5009.15-2003.In accordance with the requirements of JJF 1059-1999,the uncertainty components and the uncertainty of measurement results were evaluated.[Results]The result showed that the content of cadmium in rice was)(175 ±12) μg/kg,which was within the range of the standard value and uncertainty of standard material(180 ± 20) μg /kg.[Conclusion]The results of cadmium content in rice,which are determined by graphite furnace atomic absorption spectrometry in this laboratory,are accurate and reliable.

About this research paper

What this paper is about

[Objective]To analyze the whole determination process of cadmium in rice by graphite furnace atomic absorption spectrometry,study the influencing factors of uncertainty,and evaluate the uncertainty.[Methods]The content of cadmium in rice was detected by graphite furnace atomic absorption spectrometry according to the method of GB /T 5009.15-2003.In accordance with the requirements of JJF 1059-1999,the uncertainty components and the uncertainty of measurement results were evaluated.[Results]The result showed that the content of cadmium in rice was)(175 ±12) μg/kg,which was within the range of the standard value and uncertainty of standard material(180 ± 20) μg /kg.[Conclusion]The results of cadmium content in rice,which are determined by graphite furnace atomic absorption spectrometry in this laboratory,are accurate and reliable.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective]To analyze the whole determination process of cadmium in rice by graphite furnace atomic absorption spectrometry,study the influencing factors of uncertainty,and evaluate the uncertainty.[Methods]The content of cadmium in rice was detected by graphite furnace atomic absorption spectrometry according to the method of GB /T 5009.15-2003.In accordance with the requirements of JJF 1059-1999,the uncertainty components and the uncertainty of measurement results were evaluated.[Results]The result showed that the content of cadmium in rice was)(175 ±12) μg/kg,which was within the range of the standard value and uncertainty of standard material(180 ± 20) μg /kg.[Conclusion]The results of cadmium content in rice,which are determined by graphite furnace atomic absorption spectrometry in this laboratory,are accurate and reliable.

Key concepts: Graphite furnace atomic absorption, Cadmium, Graphite, Atomic absorption spectroscopy, Mass spectrometry, Chemistry, Analytical Chemistry (journal), Absorption (acoustics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Uncertainty evaluation in determination of cadmium in rice by graphite furnace atomic absorption spectrometry — Research Paper | ScholarLens