2012Rock and Mineral AnalysisRequires access

Determination of Silicon Dioxide in Chrome Ores by Inductively Coupled Plasma-Atomic Emission Spectrometry

Yang Hui-ling

Open publisher page 0 citations

Abstract

Chrome ore samples were digested with Na2O2.After the whole process of high temperature melting extracted with hot water-hydrochloric acid,the SiO2 in sample solutions was directly determined by Inductively Coupled Plasma-Atomic Emission Spectrometry(ICP-AES),adding Au as an internal standard element.The matrix interference is discussed in this paper.The results show that the recoveries of SiO2 are lower than 92.5% when the content of Na is higher than 300 mg/L.The matrix interference effect and the instrument fluctuation have been overcome by Au internal calibration with improved precision and accuracy of the analysis.The determination limit of SiO2 was 0.0075 mg/L and the determination content range was of 0.025%-10.0%.The results are in agreement with the certified values of the reference materials and the precision of the method is less than 2%(RSD,n=9).Compared with conventional chemical analysis,the measured values of SiO2 are in agreement with the certified values.However,the cumbersome procedure,time consuming,heavy workload of conventional chemical analysis methods can be overcome as the work efficiency is improved with this method.It can also be used for the simultaneous determination of Al,Fe,Ca,Mg and P in chrome ore samples.

About this research paper

What this paper is about

Chrome ore samples were digested with Na2O2.After the whole process of high temperature melting extracted with hot water-hydrochloric acid,the SiO2 in sample solutions was directly determined by Inductively Coupled Plasma-Atomic Emission Spectrometry(ICP-AES),adding Au as an internal standard element.The matrix interference is discussed in this paper.The results show that the recoveries of SiO2 are lower than 92.5% when the content of Na is higher than 300 mg/L.The matrix interference effect and the instrument fluctuation have been overcome by Au internal calibration with improved precision and accuracy of the analysis.The determination limit of SiO2 was 0.0075 mg/L and the determination content range was of 0.025%-10.0%.The results are in agreement with the certified values of the reference materials and the precision of the method is less than 2%(RSD,n=9).Compared with conventional chemical analysis,the measured values of SiO2 are in agreement with the certified values.However,the cumbersome procedure,time consuming,heavy workload of conventional chemical analysis methods can be overcome as the work efficiency is improved with this method.It can also be used for the simultaneous determination of Al,Fe,Ca,Mg and P in chrome ore samples.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Chrome ore samples were digested with Na2O2.After the whole process of high temperature melting extracted with hot water-hydrochloric acid,the SiO2 in sample solutions was directly determined by Inductively Coupled Plasma-Atomic Emission Spectrometry(ICP-AES),adding Au as an internal standard element.The matrix interference is discussed in this paper.The results show that the recoveries of SiO2 are lower than 92.5% when the content of Na is higher than 300 mg/L.The matrix interference effect and the instrument fluctuation have been overcome by Au internal calibration with improved precision and accuracy of the analysis.The determination limit of SiO2 was 0.0075 mg/L and the determination content range was of 0.025%-10.0%.The results are in agreement with the certified values of the reference materials and the precision of the method is less than 2%(RSD,n=9).Compared with conventional chemical analysis,the measured values of SiO2 are in agreement with the certified values.However,the cumbersome procedure,time consuming,heavy workload of conventional chemical analysis methods can be overcome as the work efficiency is improved with this method.It can also be used for the simultaneous determination of Al,Fe,Ca,Mg and P in chrome ore samples.

Key concepts: Analytical Chemistry (journal), Inductively coupled plasma, Chemistry, Certified reference materials, Detection limit, Matrix (chemical analysis), Inductively coupled plasma mass spectrometry, Inductively coupled plasma atomic emission spectroscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Silicon Dioxide in Chrome Ores by Inductively Coupled Plasma-Atomic Emission Spectrometry — Research Paper | ScholarLens