2007Chinese Journal of Analysis LaboratoryRequires access

Determination of trace sulfur in antimony by ion chromatography with adsorption column of alumina

Shi Jianrong

Open publisher page 0 citations

Abstract

A novel method of determining trace amount of sulfur in antimony with alumina adsorption column-ion chromatography was established.Antimony samples were dissolved by aqua regia,hydrobromic acid,and hydrochloric acid step wisely,converting sulfur in the samples into sulfate.Elimination of Antimony matrix,as its halides evaporated,was conducted at low temperature on a hot plate during the sample digestion.After sample solution flowed through alumina absorption column,sulfate was concentrated on the column and separated from other potential interferences.The desorption of sulfate in the column was achieved by rinsing with diluted ammonia.The sulfate in the rinsed solution was determined by ion chromatography afterwards.The experimental conditions,such as composition and flow rate of eluent,were optimized.The combination of sodium carbonate of 3.5 mmol/L and sodium bicarbonate of 1.0 mmol/L was used as an eluent with the flow rate of 1.2 mL/min.The dynamic linearity located between 0.2~100 μg/mL,the detection limit of the method was 0.2 μg/mL.And the recoveries were 92.9%~103.1%.The proposed method is fast,accurate and sensitive.This method is suitable to determine sulfur in antimony with satisfactory results.

About this research paper

What this paper is about

A novel method of determining trace amount of sulfur in antimony with alumina adsorption column-ion chromatography was established.Antimony samples were dissolved by aqua regia,hydrobromic acid,and hydrochloric acid step wisely,converting sulfur in the samples into sulfate.Elimination of Antimony matrix,as its halides evaporated,was conducted at low temperature on a hot plate during the sample digestion.After sample solution flowed through alumina absorption column,sulfate was concentrated on the column and separated from other potential interferences.The desorption of sulfate in the column was achieved by rinsing with diluted ammonia.The sulfate in the rinsed solution was determined by ion chromatography afterwards.The experimental conditions,such as composition and flow rate of eluent,were optimized.The combination of sodium carbonate of 3.5 mmol/L and sodium bicarbonate of 1.0 mmol/L was used as an eluent with the flow rate of 1.2 mL/min.The dynamic linearity located between 0.2~100 μg/mL,the detection limit of the method was 0.2 μg/mL.And the recoveries were 92.9%~103.1%.The proposed method is fast,accurate and sensitive.This method is suitable to determine sulfur in antimony with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel method of determining trace amount of sulfur in antimony with alumina adsorption column-ion chromatography was established.Antimony samples were dissolved by aqua regia,hydrobromic acid,and hydrochloric acid step wisely,converting sulfur in the samples into sulfate.Elimination of Antimony matrix,as its halides evaporated,was conducted at low temperature on a hot plate during the sample digestion.After sample solution flowed through alumina absorption column,sulfate was concentrated on the column and separated from other potential interferences.The desorption of sulfate in the column was achieved by rinsing with diluted ammonia.The sulfate in the rinsed solution was determined by ion chromatography afterwards.The experimental conditions,such as composition and flow rate of eluent,were optimized.The combination of sodium carbonate of 3.5 mmol/L and sodium bicarbonate of 1.0 mmol/L was used as an eluent with the flow rate of 1.2 mL/min.The dynamic linearity located between 0.2~100 μg/mL,the detection limit of the method was 0.2 μg/mL.And the recoveries were 92.9%~103.1%.The proposed method is fast,accurate and sensitive.This method is suitable to determine sulfur in antimony with satisfactory results.

Key concepts: Chemistry, Antimony, Column chromatography, Chromatography, Hydrochloric acid, Ion chromatography, Sulfate, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source