2009Gao dianya jishuRequires access

Application of the Flicker Simulation Method to Electric Arc Furnace Power System

Jia Hong-xin

Open publisher page 0 citations

Abstract

In order to assess the flicker caused by electric arc furnace,the simulation method to assess flicker and its application in electric arc furnace power system was studied. Firstly,based on the flickermeter-functional and design specifications recommended by IEC,an IEC flickermeter was designed concretely;Secondly,an IEC flickermeter model was established in SIMULINK,and a special M file which could be used to calculate the short-term flicker sensation indicator (Pst) was compiled,according to the IEC criterion,the flickermeter model was tested;Finally,assess of the flicker caused by an actual electric arc furnace was achieved,the instantaneous flicker sensation S(t) in the point of common coupling was gained. The results show that application of simulation method to assess the flicker caused by electric arc furnace is an effective way.

About this research paper

What this paper is about

In order to assess the flicker caused by electric arc furnace,the simulation method to assess flicker and its application in electric arc furnace power system was studied. Firstly,based on the flickermeter-functional and design specifications recommended by IEC,an IEC flickermeter was designed concretely;Secondly,an IEC flickermeter model was established in SIMULINK,and a special M file which could be used to calculate the short-term flicker sensation indicator (Pst) was compiled,according to the IEC criterion,the flickermeter model was tested;Finally,assess of the flicker caused by an actual electric arc furnace was achieved,the instantaneous flicker sensation S(t) in the point of common coupling was gained. The results show that application of simulation method to assess the flicker caused by electric arc furnace is an effective way.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to assess the flicker caused by electric arc furnace,the simulation method to assess flicker and its application in electric arc furnace power system was studied. Firstly,based on the flickermeter-functional and design specifications recommended by IEC,an IEC flickermeter was designed concretely;Secondly,an IEC flickermeter model was established in SIMULINK,and a special M file which could be used to calculate the short-term flicker sensation indicator (Pst) was compiled,according to the IEC criterion,the flickermeter model was tested;Finally,assess of the flicker caused by an actual electric arc furnace was achieved,the instantaneous flicker sensation S(t) in the point of common coupling was gained. The results show that application of simulation method to assess the flicker caused by electric arc furnace is an effective way.

Key concepts: Flicker, Electric arc furnace, Electric arc, Engineering, Arc (geometry), Power (physics), Electric power system, Electric power

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of the Flicker Simulation Method to Electric Arc Furnace Power System — Research Paper | ScholarLens