2010Surface TechnologyRequires access

Influencing Factors of Low Concentration Cuprous' Measure

XU Yu-xia

Open publisher page 0 citations

Abstract

In order to establish the optimal measure conditions of low concentration cuprous content in acidic etcher solution to improve work efficiency,titrimetry with cerium sulfate was used to study the influence of several factors on measure results by single factors,and combine with orthogonal experiment,the best results was obtained of several Influence factors.The results show that the influence of titration time,the concentration of HCl,joined volume of FeCl3,measure temperature and sample volume on measure results are outstanding,but the content of Cu2+ is indistinctively;And measured the solution that concentration of cuprous is 5 g/L,and could finish in the 5 minutes and normal temperature,the relative error is-0.8% when the concentration of HCl is 7 mol/L,joined volume of FeCl3 in the measure process is 10 mL and sample volume of solution is 10 mL.

About this research paper

What this paper is about

In order to establish the optimal measure conditions of low concentration cuprous content in acidic etcher solution to improve work efficiency,titrimetry with cerium sulfate was used to study the influence of several factors on measure results by single factors,and combine with orthogonal experiment,the best results was obtained of several Influence factors.The results show that the influence of titration time,the concentration of HCl,joined volume of FeCl3,measure temperature and sample volume on measure results are outstanding,but the content of Cu2+ is indistinctively;And measured the solution that concentration of cuprous is 5 g/L,and could finish in the 5 minutes and normal temperature,the relative error is-0.8% when the concentration of HCl is 7 mol/L,joined volume of FeCl3 in the measure process is 10 mL and sample volume of solution is 10 mL.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to establish the optimal measure conditions of low concentration cuprous content in acidic etcher solution to improve work efficiency,titrimetry with cerium sulfate was used to study the influence of several factors on measure results by single factors,and combine with orthogonal experiment,the best results was obtained of several Influence factors.The results show that the influence of titration time,the concentration of HCl,joined volume of FeCl3,measure temperature and sample volume on measure results are outstanding,but the content of Cu2+ is indistinctively;And measured the solution that concentration of cuprous is 5 g/L,and could finish in the 5 minutes and normal temperature,the relative error is-0.8% when the concentration of HCl is 7 mol/L,joined volume of FeCl3 in the measure process is 10 mL and sample volume of solution is 10 mL.

Key concepts: Measure (data warehouse), Titration, Volume (thermodynamics), Cerium, Analytical Chemistry (journal), Chemistry, Materials science, Inorganic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Influencing Factors of Low Concentration Cuprous' Measure — Research Paper | ScholarLens