2007•PubMedRequires access

[Selective laser trabeculoplasty in the treatment of primary open-angle glaucoma].

Shaohong Qian, Xinghuai Sun

Open publisher page 5 citations

Abstract

OBJECTIVE: To investigate the efficacy and safety of selective laser trabeculoplasty (SLT) in the treatment of primary open angle glaucoma (POAG). METHODS: In a prospective non-randomized clinical study, 63 patients (85 eyes) with POAG and medically uncontrolled intraocular pressure (IOP) underwent SLT. A total of 50 +/- 5 adjacent but nonoverlapping spots were placed over inferior 180 degrees of the trabecular meshwork using a 532 nm, Q-switched, Nd: YAG laser at energy levels ranging from 0.6 - 1.8 mJ per pulse. After SLT, the eyes continued to receive the identical drug regimen. All patients were observed before and 1, 2 hours, 1, 7 and 14 days, and 1, 2, 3, 6, 9, 12, 18, and 24 months after the treatment. RESULTS: The average pre-operative IOP was (25 +/- 4) mm Hg (1 mm Hg = 0.133 kPa). The mean IOP reduction from baseline were 8.1 mm Hg (32.0%) 1 day after the SLT, 5.6 mm Hg (22.1%) 7 days after the SLT, 4.7 mm Hg (18.6%) 14 days after the SLT, 5.5 mm Hg (21.7%) 1 month after the SLT, 5.1 mm Hg (20.2%) 2 months after the SLT, 5.9 mm Hg (23.3%) 3 months after the SLT, 5.2 mm Hg (20.6%) 6 months after the SLT, 4.0 mm Hg (15.8%) 9 months after the SLT, 4.2 mm Hg (16.6%) 12 months after the SLT, 3.8 mm Hg (15.0%) 18 months after the SLT, and 3.3 mm Hg (13.0%) 24 months after the SLT (P < 0.01 or 0.05). Adverse reactions were minimal, including conjunctival injection, mild anterior chamber reaction, and transient pressure spike. CONCLUSION: SLT is a safe, and effective method of reducing IOP in POAG patients.

About this research paper

What this paper is about

OBJECTIVE: To investigate the efficacy and safety of selective laser trabeculoplasty (SLT) in the treatment of primary open angle glaucoma (POAG). METHODS: In a prospective non-randomized clinical study, 63 patients (85 eyes) with POAG and medically uncontrolled intraocular pressure (IOP) underwent SLT. A total of 50 +/- 5 adjacent but nonoverlapping spots were placed over inferior 180 degrees of the trabecular meshwork using a 532 nm, Q-switched, Nd: YAG laser at energy levels ranging from 0.6 - 1.8 mJ per pulse. After SLT, the eyes continued to receive the identical drug regimen. All patients were observed before and 1, 2 hours, 1, 7 and 14 days, and 1, 2, 3, 6, 9, 12, 18, and 24 months after the treatment. RESULTS: The average pre-operative IOP was (25 +/- 4) mm Hg (1 mm Hg = 0.133 kPa). The mean IOP reduction from baseline were 8.1 mm Hg (32.0%) 1 day after the SLT, 5.6 mm Hg (22.1%) 7 days after the SLT, 4.7 mm Hg (18.6%) 14 days after the SLT, 5.5 mm Hg (21.7%) 1 month after the SLT, 5.1 mm Hg (20.2%) 2 months after the SLT, 5.9 mm Hg (23.3%) 3 months after the SLT, 5.2 mm Hg (20.6%) 6 months after the SLT, 4.0 mm Hg (15.8%) 9 months after the SLT, 4.2 mm Hg (16.6%) 12 months after the SLT, 3.8 mm Hg (15.0%) 18 months after the SLT, and 3.3 mm Hg (13.0%) 24 months after the SLT (P < 0.01 or 0.05). Adverse reactions were minimal, including conjunctival injection, mild anterior chamber reaction, and transient pressure spike. CONCLUSION: SLT is a safe, and effective method of reducing IOP in POAG patients.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To investigate the efficacy and safety of selective laser trabeculoplasty (SLT) in the treatment of primary open angle glaucoma (POAG). METHODS: In a prospective non-randomized clinical study, 63 patients (85 eyes) with POAG and medically uncontrolled intraocular pressure (IOP) underwent SLT. A total of 50 +/- 5 adjacent but nonoverlapping spots were placed over inferior 180 degrees of the trabecular meshwork using a 532 nm, Q-switched, Nd: YAG laser at energy levels ranging from 0.6 - 1.8 mJ per pulse. After SLT, the eyes continued to receive the identical drug regimen. All patients were observed before and 1, 2 hours, 1, 7 and 14 days, and 1, 2, 3, 6, 9, 12, 18, and 24 months after the treatment. RESULTS: The average pre-operative IOP was (25 +/- 4) mm Hg (1 mm Hg = 0.133 kPa). The mean IOP reduction from baseline were 8.1 mm Hg (32.0%) 1 day after the SLT, 5.6 mm Hg (22.1%) 7 days after the SLT, 4.7 mm Hg (18.6%) 14 days after the SLT, 5.5 mm Hg (21.7%) 1 month after the SLT, 5.1 mm Hg (20.2%) 2 months after the SLT, 5.9 mm Hg (23.3%) 3 months after the SLT, 5.2 mm Hg (20.6%) 6 months after the SLT, 4.0 mm Hg (15.8%) 9 months after the SLT, 4.2 mm Hg (16.6%) 12 months after the SLT, 3.8 mm Hg (15.0%) 18 months after the SLT, and 3.3 mm Hg (13.0%) 24 months after the SLT (P < 0.01 or 0.05). Adverse reactions were minimal, including conjunctival injection, mild anterior chamber reaction, and transient pressure spike. CONCLUSION: SLT is a safe, and effective method of reducing IOP in POAG patients.

Key concepts: Medicine, Trabecular meshwork, Glaucoma, Intraocular pressure, Open angle glaucoma, Ophthalmology

Related papers

Back to paper searchBrowse research topicsOriginal source
[Selective laser trabeculoplasty in the treatment of primary open-angle glaucoma]. — Research Paper | ScholarLens