2014•Proceedings of the CSEERequires access

Study on the Relationship Between Partial Discharge Development and Electrical Tree Growth in Silicone Rubber

Chang Wenzh

Open publisher page 1 citations

Abstract

Study on the relationship between microphysical processes of electrical tree and macro characterization of PD in silicone rubber, can provide a theoretical basis of cable joints' insulation condition online assessment based on PD severity. In this paper, the silicone rubber test sample with defect was made; and the electrical tree photos and PD signals were observed and measured during the deterioration process of the test sample; the time curves of electrical tree area and PD energy per unit time were obtained; the relationship between the two curves was expounded. Based on the change of electrical tree area, the development process of electrical tree was divided into three stages: growth, slow growth and rapid growth. The growth pattern of the electrical tree in every stage was discussed. The development of PD was divided into five stages according to the trend of PD energy. For each stage, the phase characteristic spectrograms were got; the cavity in PD gray images, and PD phase width were extracted to evaluate the severity of PD. The results show that, there was a highly consistency between the electrical tree curve and the PD curve. The three growth stages of electrical tree corresponded to the stage 1-2, stage 3 and stage 4-5 of PD development respectively. Thus, the relationship between electrical tree growth and PD development has been established, which laid the foundation for online assessment of the cable joint insulation condition..

About this research paper

What this paper is about

Study on the relationship between microphysical processes of electrical tree and macro characterization of PD in silicone rubber, can provide a theoretical basis of cable joints' insulation condition online assessment based on PD severity. In this paper, the silicone rubber test sample with defect was made; and the electrical tree photos and PD signals were observed and measured during the deterioration process of the test sample; the time curves of electrical tree area and PD energy per unit time were obtained; the relationship between the two curves was expounded. Based on the change of electrical tree area, the development process of electrical tree was divided into three stages: growth, slow growth and rapid growth. The growth pattern of the electrical tree in every stage was discussed. The development of PD was divided into five stages according to the trend of PD energy. For each stage, the phase characteristic spectrograms were got; the cavity in PD gray images, and PD phase width were extracted to evaluate the severity of PD. The results show that, there was a highly consistency between the electrical tree curve and the PD curve. The three growth stages of electrical tree corresponded to the stage 1-2, stage 3 and stage 4-5 of PD development respectively. Thus, the relationship between electrical tree growth and PD development has been established, which laid the foundation for online assessment of the cable joint insulation condition..

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Study on the relationship between microphysical processes of electrical tree and macro characterization of PD in silicone rubber, can provide a theoretical basis of cable joints' insulation condition online assessment based on PD severity. In this paper, the silicone rubber test sample with defect was made; and the electrical tree photos and PD signals were observed and measured during the deterioration process of the test sample; the time curves of electrical tree area and PD energy per unit time were obtained; the relationship between the two curves was expounded. Based on the change of electrical tree area, the development process of electrical tree was divided into three stages: growth, slow growth and rapid growth. The growth pattern of the electrical tree in every stage was discussed. The development of PD was divided into five stages according to the trend of PD energy. For each stage, the phase characteristic spectrograms were got; the cavity in PD gray images, and PD phase width were extracted to evaluate the severity of PD. The results show that, there was a highly consistency between the electrical tree curve and the PD curve. The three growth stages of electrical tree corresponded to the stage 1-2, stage 3 and stage 4-5 of PD development respectively. Thus, the relationship between electrical tree growth and PD development has been established, which laid the foundation for online assessment of the cable joint insulation condition..

Key concepts: Silicone rubber, Tree (set theory), Materials science, Silicone, Composite material, Forensic engineering, Mathematics, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Relationship Between Partial Discharge Development and Electrical Tree Growth in Silicone Rubber — Research Paper | ScholarLens