2008Low Temperature Architecture TechnologyRequires access

INFLUENCE FACTORS ANALYSIS OF OPTIMAL ARRANGEMENT OF NEGATIVE MOMENT STEEL IN FRAME BEAM

Yao Qian-feng

Open publisher page 0 citations

Abstract

The factors influencing frame beam negative moment steel arranged in web are discussed in frame structure.It is feasible that frame beam negative moment steel to be arranged in web if these conditions as followed are fulfilled: the RC floor thickness h≥110mm,the second row steel bar diameter D≤25mm,the floor crack is not run-through,and the crack width is less than limitation of the code.The optimized arrange manner of beam negative moment steel can insure the concrete density degree,and benefit the whole construction quality of frame structure.

About this research paper

What this paper is about

The factors influencing frame beam negative moment steel arranged in web are discussed in frame structure.It is feasible that frame beam negative moment steel to be arranged in web if these conditions as followed are fulfilled: the RC floor thickness h≥110mm,the second row steel bar diameter D≤25mm,the floor crack is not run-through,and the crack width is less than limitation of the code.The optimized arrange manner of beam negative moment steel can insure the concrete density degree,and benefit the whole construction quality of frame structure.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The factors influencing frame beam negative moment steel arranged in web are discussed in frame structure.It is feasible that frame beam negative moment steel to be arranged in web if these conditions as followed are fulfilled: the RC floor thickness h≥110mm,the second row steel bar diameter D≤25mm,the floor crack is not run-through,and the crack width is less than limitation of the code.The optimized arrange manner of beam negative moment steel can insure the concrete density degree,and benefit the whole construction quality of frame structure.

Key concepts: Structural engineering, Moment (physics), Frame (networking), Beam (structure), Bar (unit), Materials science, Steel frame, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
INFLUENCE FACTORS ANALYSIS OF OPTIMAL ARRANGEMENT OF NEGATIVE MOMENT STEEL IN FRAME BEAM — Research Paper | ScholarLens