2011Unpublished venueRequires access

Simultaneous Determination of Cd,Co,Cu,Mg,Mn,Ni,Pb,Zn and Ca in Laterite Nickel Ore by Inductively Coupled Plasma Atomic Emission Spectrometry(ICP-AES)

Feng Xianjin

Open publisher page 0 citations

Abstract

A new analytical method was proposed to simultaneously determine Cd,Co,Cu,Mg,Mn,Ni,Pb,Zn and Ca in laterite nickel ore by inductively coupled plasma atomic emission spectrometry(ICP-AES).The samples were first treated by hydrochloric acid,nitric acid and hydrofluoric acid and then determined by ICP-AES under optimal instrument conditions with hydrochloric acid as the testing medium.The detection limits for each element were 0.0001%~0.0033 μg/mL and the relative standard deviations(RSD,n=6)were 0.15%~1.89%.The recoveries for testing the spiked samples were between 91.4%~107.2%.The comparison test showed that the values determined by ICP-AES were consistent with those by flame atomic absorption spectrometry.

About this research paper

What this paper is about

A new analytical method was proposed to simultaneously determine Cd,Co,Cu,Mg,Mn,Ni,Pb,Zn and Ca in laterite nickel ore by inductively coupled plasma atomic emission spectrometry(ICP-AES).The samples were first treated by hydrochloric acid,nitric acid and hydrofluoric acid and then determined by ICP-AES under optimal instrument conditions with hydrochloric acid as the testing medium.The detection limits for each element were 0.0001%~0.0033 μg/mL and the relative standard deviations(RSD,n=6)were 0.15%~1.89%.The recoveries for testing the spiked samples were between 91.4%~107.2%.The comparison test showed that the values determined by ICP-AES were consistent with those by flame atomic absorption spectrometry.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new analytical method was proposed to simultaneously determine Cd,Co,Cu,Mg,Mn,Ni,Pb,Zn and Ca in laterite nickel ore by inductively coupled plasma atomic emission spectrometry(ICP-AES).The samples were first treated by hydrochloric acid,nitric acid and hydrofluoric acid and then determined by ICP-AES under optimal instrument conditions with hydrochloric acid as the testing medium.The detection limits for each element were 0.0001%~0.0033 μg/mL and the relative standard deviations(RSD,n=6)were 0.15%~1.89%.The recoveries for testing the spiked samples were between 91.4%~107.2%.The comparison test showed that the values determined by ICP-AES were consistent with those by flame atomic absorption spectrometry.

Key concepts: Inductively coupled plasma, Inductively coupled plasma atomic emission spectroscopy, Hydrochloric acid, Atomic absorption spectroscopy, Chemistry, Nitric acid, Nickel, Laterite

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Determination of Cd,Co,Cu,Mg,Mn,Ni,Pb,Zn and Ca in Laterite Nickel Ore by Inductively Coupled Plasma Atomic Emission Spectrometry(ICP-AES) — Research Paper | ScholarLens