2001PubMedRequires access

[A preliminary study of a hearing screening model for newborn].

Liu Z, Bu X, Guangqian Xing, Lu Liu

Open publisher page 6 citations

Abstract

OBJECTIVE: To search for a hearing screening model for newborn and to investigate the prevalence of newborn hearing loss in our country. METHODS: The distortion product otoacoustic emissions (DPOAE) was used to test the hearing in 2,998 of 3,075 newborns before discharge. Otoacoustic emissions (OAE) was again used for cases failed in the hospital screening 4 weeks later. Those cases failed in both screening steps were finally tested by auditory brainstem response (ABR). All infants failed in ABR test received diagnostic evaluation audiologically to identify the category and degree of hearing loss. The pass criterion of DPOAE was defined as signal-noise-ratio (SNR) exceeding 6 dB in 4 of 5 frequencies between 1.5-6 kHz. The pass criterion of ABR was the presence of wave V in response to 35 dB nHL click stimuli. RESULTS: The OAE screening in the hospital showed that 2,710 (90.4%) newborns passed the first test. Two hundred and sixty three of 288 newborns passed the second OAE screening after one month. Six of 25 infants failed in ABR test were eventually identified to be hearing impaired. CONCLUSION: Two-stages screening, combining OAE and ABR tests, may be an ideal model for newborn hearing screening. The prevalence of congenital hearing loss is similar to that reported in the literature.

About this research paper

What this paper is about

OBJECTIVE: To search for a hearing screening model for newborn and to investigate the prevalence of newborn hearing loss in our country. METHODS: The distortion product otoacoustic emissions (DPOAE) was used to test the hearing in 2,998 of 3,075 newborns before discharge. Otoacoustic emissions (OAE) was again used for cases failed in the hospital screening 4 weeks later. Those cases failed in both screening steps were finally tested by auditory brainstem response (ABR). All infants failed in ABR test received diagnostic evaluation audiologically to identify the category and degree of hearing loss. The pass criterion of DPOAE was defined as signal-noise-ratio (SNR) exceeding 6 dB in 4 of 5 frequencies between 1.5-6 kHz. The pass criterion of ABR was the presence of wave V in response to 35 dB nHL click stimuli. RESULTS: The OAE screening in the hospital showed that 2,710 (90.4%) newborns passed the first test. Two hundred and sixty three of 288 newborns passed the second OAE screening after one month. Six of 25 infants failed in ABR test were eventually identified to be hearing impaired. CONCLUSION: Two-stages screening, combining OAE and ABR tests, may be an ideal model for newborn hearing screening. The prevalence of congenital hearing loss is similar to that reported in the literature.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To search for a hearing screening model for newborn and to investigate the prevalence of newborn hearing loss in our country. METHODS: The distortion product otoacoustic emissions (DPOAE) was used to test the hearing in 2,998 of 3,075 newborns before discharge. Otoacoustic emissions (OAE) was again used for cases failed in the hospital screening 4 weeks later. Those cases failed in both screening steps were finally tested by auditory brainstem response (ABR). All infants failed in ABR test received diagnostic evaluation audiologically to identify the category and degree of hearing loss. The pass criterion of DPOAE was defined as signal-noise-ratio (SNR) exceeding 6 dB in 4 of 5 frequencies between 1.5-6 kHz. The pass criterion of ABR was the presence of wave V in response to 35 dB nHL click stimuli. RESULTS: The OAE screening in the hospital showed that 2,710 (90.4%) newborns passed the first test. Two hundred and sixty three of 288 newborns passed the second OAE screening after one month. Six of 25 infants failed in ABR test were eventually identified to be hearing impaired. CONCLUSION: Two-stages screening, combining OAE and ABR tests, may be an ideal model for newborn hearing screening. The prevalence of congenital hearing loss is similar to that reported in the literature.

Key concepts: Medicine, Audiology, Hearing loss, Auditory brainstem response, Otoacoustic emission, Unilateral hearing loss, Newborn screening, Screening test

Related papers

Back to paper searchBrowse research topicsOriginal source
[A preliminary study of a hearing screening model for newborn]. — Research Paper | ScholarLens