2010•Guangzhou Chemical IndustryRequires access

HPLC Determination of Cinnamaldehyde in Rouguiyou Cataplasma

Xiao‐Ping Lai

Open publisher page 0 citations

Abstract

A method for the determination of the content of cinnamaldehyde in Rouguiyou cataplasma was established.HPLC was used with a DiamoonsilC18(2)(4.6mm×250mm,5μm),the mobile phase was acetonitril-water-acetic acid(50:5:0.3),the flow rate was 1.0 mL·min-1 and the detection wavelength was 290nm.The linear range of cinnamaldehyde was 1.4625~46.8μg /mL,and the average recovery was 98.12%.The results were accurate and reproducible,and the method was suitable for the determination of cinnamaldehyde in Rouguiyou cataplasma.

About this research paper

What this paper is about

A method for the determination of the content of cinnamaldehyde in Rouguiyou cataplasma was established.HPLC was used with a DiamoonsilC18(2)(4.6mm×250mm,5μm),the mobile phase was acetonitril-water-acetic acid(50:5:0.3),the flow rate was 1.0 mL·min-1 and the detection wavelength was 290nm.The linear range of cinnamaldehyde was 1.4625~46.8μg /mL,and the average recovery was 98.12%.The results were accurate and reproducible,and the method was suitable for the determination of cinnamaldehyde in Rouguiyou cataplasma.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of the content of cinnamaldehyde in Rouguiyou cataplasma was established.HPLC was used with a DiamoonsilC18(2)(4.6mm×250mm,5μm),the mobile phase was acetonitril-water-acetic acid(50:5:0.3),the flow rate was 1.0 mL·min-1 and the detection wavelength was 290nm.The linear range of cinnamaldehyde was 1.4625~46.8μg /mL,and the average recovery was 98.12%.The results were accurate and reproducible,and the method was suitable for the determination of cinnamaldehyde in Rouguiyou cataplasma.

Key concepts: Cinnamaldehyde, High-performance liquid chromatography, Chromatography, Chemistry, Acetic acid, Linear range, Detection limit, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
HPLC Determination of Cinnamaldehyde in Rouguiyou Cataplasma — Research Paper | ScholarLens