2009Continuous CastingRequires access

Study on Optimizing Flow Control Devices for Slab Continuous Casting Tundish by Water Modeling

Jinzhong Xiang

Open publisher page 0 citations

Abstract

Water model experiments were taken to install proper flow control devices for a slab continuous casting tundish.Cases of weir + dam were optimized by orthogonal experiments.The results show that there are short circuit flow and large dead volume in the tundish without flow control devices.Case 3 can obviously improve the flow field,which lengthens the average residence time,makes dead volume decrease,plug volume increase.Furthermore,the flow is close to the surface when case 3 is used,which is helpful for inclusion removal.

About this research paper

What this paper is about

Water model experiments were taken to install proper flow control devices for a slab continuous casting tundish.Cases of weir + dam were optimized by orthogonal experiments.The results show that there are short circuit flow and large dead volume in the tundish without flow control devices.Case 3 can obviously improve the flow field,which lengthens the average residence time,makes dead volume decrease,plug volume increase.Furthermore,the flow is close to the surface when case 3 is used,which is helpful for inclusion removal.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Water model experiments were taken to install proper flow control devices for a slab continuous casting tundish.Cases of weir + dam were optimized by orthogonal experiments.The results show that there are short circuit flow and large dead volume in the tundish without flow control devices.Case 3 can obviously improve the flow field,which lengthens the average residence time,makes dead volume decrease,plug volume increase.Furthermore,the flow is close to the surface when case 3 is used,which is helpful for inclusion removal.

Key concepts: Tundish, Water model, Slab, Continuous casting, Flow (mathematics), Flow control (data), Plug flow, Volume (thermodynamics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on Optimizing Flow Control Devices for Slab Continuous Casting Tundish by Water Modeling — Research Paper | ScholarLens